Determination of haemoglobin in gastric aspirates.
Λέξεις-κλειδιά
Αφηρημένη
The haemoglobin content of gastric aspirates can be quantitated by conversion of non-fluorescent haem to fluorescent porphyrins by heating gastric aspirates with oxalic acid and ferrous sulphate. Recovery of haemoglobin added to gastric aspirates was 92 +/- 9%, variation coefficient, n = 52, day to day variation less than 8%. This method was used to calculate blood (haemoglobin) loss in 211 (24 hours) gastric aspirates obtained from 58 intensive care patients. Gastric blood loss was also measured by the 51Cr radiolabelled erythrocytes method in the same samples. There was a good linear correlation (r = 0.942, p less than 0.001) between the two methods. The fluorimetric method of quantitating haem is therefore suitable for detecting and measuring blood loss in gastric contents.