Greek
Albanian
Arabic
Armenian
Azerbaijani
Belarusian
Bengali
Bosnian
Catalan
Czech
Danish
Deutsch
Dutch
English
Estonian
Finnish
Français
Greek
Haitian Creole
Hebrew
Hindi
Hungarian
Icelandic
Indonesian
Irish
Italian
Japanese
Korean
Latvian
Lithuanian
Macedonian
Mongolian
Norwegian
Persian
Polish
Portuguese
Romanian
Russian
Serbian
Slovak
Slovenian
Spanish
Swahili
Swedish
Turkish
Ukrainian
Vietnamese
Български
中文(简体)
中文(繁體)
International Journal of Artificial Organs 2019-Oct

Exercise-induced hypoxemia predicts heart failure hospitalization and death in patients supported with left ventricular assist devices.

Μόνο εγγεγραμμένοι χρήστες μπορούν να μεταφράσουν άρθρα
Σύνδεση εγγραφή
Ο σύνδεσμος αποθηκεύεται στο πρόχειρο
Daniel Koerber
Andrew Rosenbaum
Thomas Olson
Sudhir Kushwaha
John Stulak
Simon Maltais
Atta Behfar

Λέξεις-κλειδιά

Αφηρημένη

Following implantation of continuous-flow left ventricular assist devices, mechanical off-loading results in improved resting hemodynamics; however, peak exercise capacity generally does not increase substantially. This study evaluated patients supported by continuous-flow left ventricular assist devices who were invasively monitored during exercise to define parameters that underpin exercise capacity and outcomes. A review of all patients supported by continuous-flow left ventricular assist devices who underwent supine bicycle ergometry exercise testing with measurement of pulmonary gas exchange during right heart catheterization for evaluation of dyspnea at one institution between 2007 and 2018 was performed (n = 22). The primary outcome of this investigation was death or heart failure hospitalization. Although resting filling pressures were relatively preserved, resting cardiac index (Fick) was low (2.1 ± 0.5 mL/kg/min). An impaired cardiac output reserve was present in 75% of patients. On univariate modeling, patients with supine exercise-induced hypoxemia (O2 saturation <90%) experienced significantly diminished hospitalization-free survival (unadjusted hazard ratio = 11.0, confidence interval = 2.4-57.2, p = 0.003), which persisted despite adjustment for right heart catheterization peak VO2 and peak cardiac output (adjusted hazard ratio = 25, confidence interval = 3.6-322, p = 0.001). Our findings suggest that supine exercise testing provides additional prognostic utility in the continuous-flow left ventricular assist device population.

Γίνετε μέλος της σελίδας
μας στο facebook

Η πληρέστερη βάση δεδομένων φαρμακευτικών βοτάνων που υποστηρίζεται από την επιστήμη

  • Λειτουργεί σε 55 γλώσσες
  • Βοτανικές θεραπείες που υποστηρίζονται από την επιστήμη
  • Αναγνώριση βοτάνων με εικόνα
  • Διαδραστικός χάρτης GPS - ετικέτα βότανα στην τοποθεσία (σύντομα)
  • Διαβάστε επιστημονικές δημοσιεύσεις που σχετίζονται με την αναζήτησή σας
  • Αναζήτηση φαρμακευτικών βοτάνων με τα αποτελέσματά τους
  • Οργανώστε τα ενδιαφέροντά σας και μείνετε ενημερωμένοι με την έρευνα ειδήσεων, τις κλινικές δοκιμές και τα διπλώματα ευρεσιτεχνίας

Πληκτρολογήστε ένα σύμπτωμα ή μια ασθένεια και διαβάστε για βότανα που μπορεί να βοηθήσουν, πληκτρολογήστε ένα βότανο και δείτε ασθένειες και συμπτώματα κατά των οποίων χρησιμοποιείται.
* Όλες οι πληροφορίες βασίζονται σε δημοσιευμένη επιστημονική έρευνα

Google Play badgeApp Store badge