Archives of pathology & laboratory medicine 2009-Mar

Inaccurate doses of R immune globulin after rh-incompatible fetomaternal hemorrhage: survey of laboratory practice.

Μόνο εγγεγραμμένοι χρήστες μπορούν να μεταφράσουν άρθρα
Σύνδεση εγγραφή
Ο σύνδεσμος αποθηκεύεται στο πρόχειρο
Glenn Ramsey
College of American Pathologists Transfusion Medicine Resource Committee

Λέξεις-κλειδιά

Αφηρημένη

BACKGROUND

Rh(D)-negative women with a large fetomaternal hemorrhage (FMH) from an Rh(D)-positive fetus are at risk for anti-D alloimmunization if they do not receive adequate Rh immune globulin (RhIG). Determination of the adequate RhIG dose for these women is a critical laboratory procedure for protecting their future Rh(D)-positive children.

OBJECTIVE

To determine how often laboratories recommended an inaccurate dose of RhIG for excess FMH.

METHODS

Nearly 1600 laboratories using the College of American Pathologists' proficiency testing for fetal red blood cell detection were surveyed to determine (1) their calculation method and (2) the number of RhIG doses recommended for a survey specimen, based on their measured percentage of fetal red blood cells. We surveyed nearly 1450 laboratories for their accuracy in determining RhIG dose, using 2 common calculation methods we provided.

RESULTS

The AABB Technical Manual method was used by 67% of responding laboratories. However, 20.7% of laboratories using this method would have recommended an inaccurate dose of RhIG--11.5% too much and 9.2% too little--for the level of FMH reported in the survey specimen. If all laboratories had used the common recommendation of 300 microg/30 mL of fetal blood present, 2% would have recommended RhIG doses too low for the volume of FMH they measured. In 3 of the 4 calculation exercises we provided, 20% to 30% of laboratories underestimated the necessary dose of RhIG.

CONCLUSIONS

Based on our surveys, some mothers with excess FMH may be receiving inaccurate doses of RhIG. Laboratories performing quantification of FMH should review their procedures and training for calculating RhIG dosage.

Γίνετε μέλος της σελίδας
μας στο facebook

Η πληρέστερη βάση δεδομένων φαρμακευτικών βοτάνων που υποστηρίζεται από την επιστήμη

  • Λειτουργεί σε 55 γλώσσες
  • Βοτανικές θεραπείες που υποστηρίζονται από την επιστήμη
  • Αναγνώριση βοτάνων με εικόνα
  • Διαδραστικός χάρτης GPS - ετικέτα βότανα στην τοποθεσία (σύντομα)
  • Διαβάστε επιστημονικές δημοσιεύσεις που σχετίζονται με την αναζήτησή σας
  • Αναζήτηση φαρμακευτικών βοτάνων με τα αποτελέσματά τους
  • Οργανώστε τα ενδιαφέροντά σας και μείνετε ενημερωμένοι με την έρευνα ειδήσεων, τις κλινικές δοκιμές και τα διπλώματα ευρεσιτεχνίας

Πληκτρολογήστε ένα σύμπτωμα ή μια ασθένεια και διαβάστε για βότανα που μπορεί να βοηθήσουν, πληκτρολογήστε ένα βότανο και δείτε ασθένειες και συμπτώματα κατά των οποίων χρησιμοποιείται.
* Όλες οι πληροφορίες βασίζονται σε δημοσιευμένη επιστημονική έρευνα

Google Play badgeApp Store badge