Greek
Albanian
Arabic
Armenian
Azerbaijani
Belarusian
Bengali
Bosnian
Catalan
Czech
Danish
Deutsch
Dutch
English
Estonian
Finnish
Français
Greek
Haitian Creole
Hebrew
Hindi
Hungarian
Icelandic
Indonesian
Irish
Italian
Japanese
Korean
Latvian
Lithuanian
Macedonian
Mongolian
Norwegian
Persian
Polish
Portuguese
Romanian
Russian
Serbian
Slovak
Slovenian
Spanish
Swahili
Swedish
Turkish
Ukrainian
Vietnamese
Български
中文(简体)
中文(繁體)
Allergy, Asthma and Clinical Immunology 2019

Severe anaphylaxis after pelvic examination: a case report of dual latex and chlorhexidine allergies.

Μόνο εγγεγραμμένοι χρήστες μπορούν να μεταφράσουν άρθρα
Σύνδεση εγγραφή
Ο σύνδεσμος αποθηκεύεται στο πρόχειρο
Mongkhon Sompornrattanaphan
Piyawut Kreetapirom
Yuttana Srinoulprasert
Duangjit Kanistanon
Anchalika Klinniyom
Chamard Wongsa
Torpong Thongngarm

Λέξεις-κλειδιά

Αφηρημένη

Natural rubber latex and chlorhexidine have previously been identified as causative substances in perioperative anaphylaxis. A pelvic examinations is generally considered noninvasive, however, this procedure is rarely associated with severe allergic reactions. We reported a rare case of dual latex and chlorhexidine allergies which caused anaphylaxis after pelvic examination in a woman with a history of latex-related fruits allergy.A 54-year-old woman had severe anaphylaxis after a pelvic examination due to dual latex and chlorhexidine (CHX) allergies. The gynecologist used CHX for the vaginal preparation and wore latex-containing gloves with lubricating gel during the examination. In vivo and in vitro tests revealed CHX sensitization by a positive skin prick test to chlorhexidine at a very low concentration (0.002 mg/mL), and a positive basophil activation test to CHX. Latex allergy was confirmed by a positive specific IgE to latex and a positive glove-use test at 20 min. An analysis of specific IgE to latex component revealed positive results for Hev b 1, 5, 6.02, and 11. As she also had a past history of fruit allergy, prick-to-prick testing with latex-related fruits was performed. The results were positive for avocado, banana, jackfruit, kiwi, and longan.Concomitant mucosal exposure of both natural rubber latex and CHX in highly sensitized patients during pelvic examinations can lead to severe anaphylaxis. Pre-procedural screening for an allergy to latex or CHX, or to any other allergen, should be performed in patients where there is suspicion of a specific allergy due to a previous allergic reaction. Increased awareness of these two allergens in all healthcare settings may improve patient safety.

Γίνετε μέλος της σελίδας
μας στο facebook

Η πληρέστερη βάση δεδομένων φαρμακευτικών βοτάνων που υποστηρίζεται από την επιστήμη

  • Λειτουργεί σε 55 γλώσσες
  • Βοτανικές θεραπείες που υποστηρίζονται από την επιστήμη
  • Αναγνώριση βοτάνων με εικόνα
  • Διαδραστικός χάρτης GPS - ετικέτα βότανα στην τοποθεσία (σύντομα)
  • Διαβάστε επιστημονικές δημοσιεύσεις που σχετίζονται με την αναζήτησή σας
  • Αναζήτηση φαρμακευτικών βοτάνων με τα αποτελέσματά τους
  • Οργανώστε τα ενδιαφέροντά σας και μείνετε ενημερωμένοι με την έρευνα ειδήσεων, τις κλινικές δοκιμές και τα διπλώματα ευρεσιτεχνίας

Πληκτρολογήστε ένα σύμπτωμα ή μια ασθένεια και διαβάστε για βότανα που μπορεί να βοηθήσουν, πληκτρολογήστε ένα βότανο και δείτε ασθένειες και συμπτώματα κατά των οποίων χρησιμοποιείται.
* Όλες οι πληροφορίες βασίζονται σε δημοσιευμένη επιστημονική έρευνα

Google Play badgeApp Store badge