Greek
Albanian
Arabic
Armenian
Azerbaijani
Belarusian
Bengali
Bosnian
Catalan
Czech
Danish
Deutsch
Dutch
English
Estonian
Finnish
Français
Greek
Haitian Creole
Hebrew
Hindi
Hungarian
Icelandic
Indonesian
Irish
Italian
Japanese
Korean
Latvian
Lithuanian
Macedonian
Mongolian
Norwegian
Persian
Polish
Portuguese
Romanian
Russian
Serbian
Slovak
Slovenian
Spanish
Swahili
Swedish
Turkish
Ukrainian
Vietnamese
Български
中文(简体)
中文(繁體)
Journal of Chromatography A 2019-Jun

The use of a plant enzyme for rapid and sensitive analysis of naturally-occurring folates in food by liquid chromatography-tandem mass spectrometry.

Μόνο εγγεγραμμένοι χρήστες μπορούν να μεταφράσουν άρθρα
Σύνδεση εγγραφή
Ο σύνδεσμος αποθηκεύεται στο πρόχειρο
Petra Ložnjak
Carolina García-Salinas
Rocío de la Garza
Anette Bysted
Jette Jakobsen

Λέξεις-κλειδιά

Αφηρημένη

A rapid, sensitive and reproducible method for analysis of naturally-occurring folates and folic acid in food has been developed and validated. A single-enzyme extraction step, in which a pure recombinant enzyme of plant origin (Arabidopsis thaliana) was used, enabled fast and reproducible deglutamylation during folate extraction within the incubation time of 1 h. Six commonly occurring folate forms (tetrahydrofolate, 5,10-methenyltetrahydrofolate, 10-formylfolic acid, 5-formyltetrahydrofolate, folic acid and 5-methyltetrahydrofolate) were detected and quantified in 9 min using liquid chromatography-tandem mass spectrometry (LC-MS/MS). 13C5-labeled 5-formyltetrahydrofolate, 13C5-labeled folic acid and 13C5-labeled 5-methyltetrahydrofolate were used as internal standards for the quantification. The method is described by a calibration curve (R2>0.99 and trueness 85-115%), a limit of quantification at 0.1 μg/100 g, trueness at 80-120% in spiked samples and certified reference materials, and a precision <10%. However, the precision in quantification of tetrahydrofolate was not within the acceptable limits due to the lack of use of the corresponding internal standard. An interconversion study of unstable formyl forms was performed which showed that 50% of 5,10-methenyltetrahydrofolate is converted to 5-formyltetrahydrofolate during the analysis. The developed LC-MS/MS method is a candidate for a future standard method for folate analysis in food.

Γίνετε μέλος της σελίδας
μας στο facebook

Η πληρέστερη βάση δεδομένων φαρμακευτικών βοτάνων που υποστηρίζεται από την επιστήμη

  • Λειτουργεί σε 55 γλώσσες
  • Βοτανικές θεραπείες που υποστηρίζονται από την επιστήμη
  • Αναγνώριση βοτάνων με εικόνα
  • Διαδραστικός χάρτης GPS - ετικέτα βότανα στην τοποθεσία (σύντομα)
  • Διαβάστε επιστημονικές δημοσιεύσεις που σχετίζονται με την αναζήτησή σας
  • Αναζήτηση φαρμακευτικών βοτάνων με τα αποτελέσματά τους
  • Οργανώστε τα ενδιαφέροντά σας και μείνετε ενημερωμένοι με την έρευνα ειδήσεων, τις κλινικές δοκιμές και τα διπλώματα ευρεσιτεχνίας

Πληκτρολογήστε ένα σύμπτωμα ή μια ασθένεια και διαβάστε για βότανα που μπορεί να βοηθήσουν, πληκτρολογήστε ένα βότανο και δείτε ασθένειες και συμπτώματα κατά των οποίων χρησιμοποιείται.
* Όλες οι πληροφορίες βασίζονται σε δημοσιευμένη επιστημονική έρευνα

Google Play badgeApp Store badge