Greek
Albanian
Arabic
Armenian
Azerbaijani
Belarusian
Bengali
Bosnian
Catalan
Czech
Danish
Deutsch
Dutch
English
Estonian
Finnish
Français
Greek
Haitian Creole
Hebrew
Hindi
Hungarian
Icelandic
Indonesian
Irish
Italian
Japanese
Korean
Latvian
Lithuanian
Macedonian
Mongolian
Norwegian
Persian
Polish
Portuguese
Romanian
Russian
Serbian
Slovak
Slovenian
Spanish
Swahili
Swedish
Turkish
Ukrainian
Vietnamese
Български
中文(简体)
中文(繁體)
Biology of the neonate 1998

Value of myocardial hypoxia markers (creatine kinase and its MB-fraction, troponin-T, QT-intervals) and serum creatinine for the retrospective diagnosis of perinatal asphyxia.

Μόνο εγγεγραμμένοι χρήστες μπορούν να μεταφράσουν άρθρα
Σύνδεση εγγραφή
Ο σύνδεσμος αποθηκεύεται στο πρόχειρο
J C Möller
B Thielsen
T F Schaible
I Reiss
M Kohl
T Welp
L Gortner

Λέξεις-κλειδιά

Αφηρημένη

Neonatal asphyxia is a major topic of neonatal research. However, no clear-cut physiologic parameters exist which enable an early identification of neonatal infants who are either at risk to develop brain damage or posthypoxic heart failure. Parameters indicating dysfunction of the heart and kidneys as creatinine and creatinine kinase have been evaluated. In our study, 47 asphyxiated infants (umbilical artery pH < 7.18 and either a 1-min Apgar score < 4 or a 5-min Apgar score < 7) were compared to 27 nonasphyxiated controls regarding significant differences in creatinine, creatinine kinase, its MB fraction, and a newly introduced myocardial hypoxia indicator -- troponin T -- to establish the value of these parameters in the retrospective diagnosis of asphyxia. Further we evaluated two subsets of these 47 asphyxiated infants with either subsequent signs of encephalopathy (seizures) or heart failure. Creatinine, creatinine kinase and troponin T were significantly elevated in asphyxiated infants compared with controls; no differences were found in creatinine kinase and its MB fraction. In asphyxiated infants with heart failure, troponin T was significantly higher than in the other asphyxiated infants. However, none of the parameters studied was significantly different in patients with brain damage compared with asphyxiated infants without neurological sequelae. Troponin T has a high positive predictive value in the postnatal diagnosis of asphyxia. The diagnostic power of troponin T equals that of creatinine. However, troponin T is more sensitive in the identification of infants with asphyxia and cardiocirculatory failure than creatinine. Creatinine kinase and its MB fraction have no diagnostic value.

Γίνετε μέλος της σελίδας
μας στο facebook

Η πληρέστερη βάση δεδομένων φαρμακευτικών βοτάνων που υποστηρίζεται από την επιστήμη

  • Λειτουργεί σε 55 γλώσσες
  • Βοτανικές θεραπείες που υποστηρίζονται από την επιστήμη
  • Αναγνώριση βοτάνων με εικόνα
  • Διαδραστικός χάρτης GPS - ετικέτα βότανα στην τοποθεσία (σύντομα)
  • Διαβάστε επιστημονικές δημοσιεύσεις που σχετίζονται με την αναζήτησή σας
  • Αναζήτηση φαρμακευτικών βοτάνων με τα αποτελέσματά τους
  • Οργανώστε τα ενδιαφέροντά σας και μείνετε ενημερωμένοι με την έρευνα ειδήσεων, τις κλινικές δοκιμές και τα διπλώματα ευρεσιτεχνίας

Πληκτρολογήστε ένα σύμπτωμα ή μια ασθένεια και διαβάστε για βότανα που μπορεί να βοηθήσουν, πληκτρολογήστε ένα βότανο και δείτε ασθένειες και συμπτώματα κατά των οποίων χρησιμοποιείται.
* Όλες οι πληροφορίες βασίζονται σε δημοσιευμένη επιστημονική έρευνα

Google Play badgeApp Store badge