English
Albanian
Arabic
Armenian
Azerbaijani
Belarusian
Bengali
Bosnian
Catalan
Czech
Danish
Deutsch
Dutch
English
Estonian
Finnish
Français
Greek
Haitian Creole
Hebrew
Hindi
Hungarian
Icelandic
Indonesian
Irish
Italian
Japanese
Korean
Latvian
Lithuanian
Macedonian
Mongolian
Norwegian
Persian
Polish
Portuguese
Romanian
Russian
Serbian
Slovak
Slovenian
Spanish
Swahili
Swedish
Turkish
Ukrainian
Vietnamese
Български
中文(简体)
中文(繁體)
Journal of Chromatography B: Analytical Technologies in the Biomedical and Life Sciences 2018-May

Determination of plasma Levetiracetam level by Liquid Chromatography-Tandem Mass Spectrometry (LC-MS-MS) and its application in pharmacokinetics studies in neonates.

Only registered users can translate articles
Log In/Sign up
The link is saved to the clipboard
Nuttawut Jenjirattithigarn
Nattha Worachat
Suchawadee Horsuwan
Apichaya Puangpetch
Chatchay Prempunpong
Chaiyos Khongkhatithum
Lunliya Thampratankul
Santirat Prommas
Anannit Visudtibhan
Chonlaphat Sukasem

Keywords

Abstract

BACKGROUND

Levetiracetam (LEV) is an antiepileptic drug which has good safety and efficacy in neonatal seizure (NS), a common incident in neonates with weight <1500 g. The pharmacokinetics for LEV in neonatal populations is yet to be clearly understood. In this study, we developed and validated a method for determination of LEV in plasma by liquid chromatography tandem mass spectrometry for the purpose of pharmacokinetic study.

METHODS

Plasma LEV was spiked with Lamivudine as internal standard before extraction by C18 solid-phase extraction (SPE) cartridge. Chromatography was performed using isocratic elution with mobile phase A: B (10: 90) for 2.0 min with flow rate 0.4 mL/min. The mobile phase was composed of 0.1% formic acid in 10.0 mM ammonium acetate (A) and 100% methanol (B). The injection volume was 1.0 μL and the total run time was 2.0 min. Multiple reaction monitoring (MRM) with electro spray in positive mode was used. The mass transition for LEV was 171.2/126.0 and 230.0/112.0 for IS with retention time of 0.73 and 0.72 min, respectively.

RESULTS

A calibration curve range from 0.50-80.0 μg/mL was obtained with a correlation coefficient >0.99 in the quadratic model. Precision and accuracy was within the acceptable range and the intra- and inter-day %CV for three concentrations of QCs were <10%.

CONCLUSIONS

This method was reliable, accurate and applicable for LEV pharmacokinetic study in neonates with seizure.

Join our facebook page

The most complete medicinal herbs database backed by science

  • Works in 55 languages
  • Herbal cures backed by science
  • Herbs recognition by image
  • Interactive GPS map - tag herbs on location (coming soon)
  • Read scientific publications related to your search
  • Search medicinal herbs by their effects
  • Organize your interests and stay up do date with the news research, clinical trials and patents

Type a symptom or a disease and read about herbs that might help, type a herb and see diseases and symptoms it is used against.
*All information is based on published scientific research

Google Play badgeApp Store badge