English
Albanian
Arabic
Armenian
Azerbaijani
Belarusian
Bengali
Bosnian
Catalan
Czech
Danish
Deutsch
Dutch
English
Estonian
Finnish
Français
Greek
Haitian Creole
Hebrew
Hindi
Hungarian
Icelandic
Indonesian
Irish
Italian
Japanese
Korean
Latvian
Lithuanian
Macedonian
Mongolian
Norwegian
Persian
Polish
Portuguese
Romanian
Russian
Serbian
Slovak
Slovenian
Spanish
Swahili
Swedish
Turkish
Ukrainian
Vietnamese
Български
中文(简体)
中文(繁體)
Eye and Contact Lens 2009-Jul

Evaluation of the role of ProKera in the management of ocular surface and orbital disorders.

Only registered users can translate articles
Log In/Sign up
The link is saved to the clipboard
Gowri Pachigolla
Pawan Prasher
Mario A Di Pascuale
James P McCulley
John G McHenry
V Vinod Mootha

Keywords

Abstract

OBJECTIVE

To report the efficacy and safety profile of sutureless and adhesiveless amniotic membrane device (ProKera, Bio-Tissue, Inc., Miami, FL) in the management of various ocular surface and orbital disorders.

METHODS

Twenty eyes of 20 patients underwent placement of 21 ProKera implants between March 2006 and July 2007 at the University of Texas Southwestern Medical Center. Patient demographics, indications for placement, and duration of ProKera retention were recorded. Outcomes measured included corneal epithelial healing, visual acuity, patient tolerance, and adverse events.

RESULTS

ProKera was most commonly used in patients with corneal neovascularization with or without limbal stem-cell deficiency (10 eyes). Other indications included recurrent pterygium or pseudopterygium (three eyes), anophthalmic orbit contraction (two eyes), persistent epithelial defects (two eyes), severe thinning in a corneal ulcer (one eye), benign hereditary intraepithelial dyskeratosis (one eye), and band keratopathy (one eye). The mean duration of ProKera retention was 25.3 days (range, 0-125) visual acuity improved in 12 eyes (60%). Immediate adverse events included residual epithelial defects after removal (five eyes) and spontaneous extrusion of the implant (four eyes). Six patients (30%) reported eye pain or headache and four eyes (20%) had recurrence of the primary pathology.

CONCLUSIONS

Sutureless and adhesiveless amniotic membrane transplantation is a safe and effective method to promote healing and reconstruction of the ocular surface and orbit with minimal side effects. Recurrence of the underlying primary pathology remains a concern. The advent of a newer, softer conformer ring may improve patient tolerability and limit discomfort.

Join our facebook page

The most complete medicinal herbs database backed by science

  • Works in 55 languages
  • Herbal cures backed by science
  • Herbs recognition by image
  • Interactive GPS map - tag herbs on location (coming soon)
  • Read scientific publications related to your search
  • Search medicinal herbs by their effects
  • Organize your interests and stay up do date with the news research, clinical trials and patents

Type a symptom or a disease and read about herbs that might help, type a herb and see diseases and symptoms it is used against.
*All information is based on published scientific research

Google Play badgeApp Store badge