English
Albanian
Arabic
Armenian
Azerbaijani
Belarusian
Bengali
Bosnian
Catalan
Czech
Danish
Deutsch
Dutch
English
Estonian
Finnish
Français
Greek
Haitian Creole
Hebrew
Hindi
Hungarian
Icelandic
Indonesian
Irish
Italian
Japanese
Korean
Latvian
Lithuanian
Macedonian
Mongolian
Norwegian
Persian
Polish
Portuguese
Romanian
Russian
Serbian
Slovak
Slovenian
Spanish
Swahili
Swedish
Turkish
Ukrainian
Vietnamese
Български
中文(简体)
中文(繁體)
Analytical Chemistry 2010-Apr

Fast and selective microfluidic chips for electrochemical antioxidant sensing in complex samples.

Only registered users can translate articles
Log In/Sign up
The link is saved to the clipboard
Nikolay Kovachev
Antonio Canals
Alberto Escarpa

Keywords

Abstract

In this work, capillary electrophoresis chips with electrochemical detection have been assessed as creative and selective microfluidic platforms to integrate and simplify on a microscale the traditional methods for complex natural antioxidants determination. Depending on the acid-base properties of the analytes, two approaches (class-selective electrochemical index determination (CSEID) and individual antioxidant determination (IAD)) were investigated for the analysis of nine antioxidants ((+)-catechin, rutin, quercetin, chlorogenic, ferulic, caffeic, protocatechuic, vanillic, and gallic acids) in food samples. First, the novel concept of a class-selective electrochemical index is proposed allowing a fast and reliable determination of the main antioxidant classes (flavonoids and phenolic acids) in less than 100 s. In addition, an impressive separation of nine antioxidants is also offered in less than 260 s with the individual antioxidant determination approach. Qualitative and quantitative performances of both approaches were studied. The analytical figures of merit (i.e., electroosmotic flow (EOF) precision as relative standard deviation (RSD), resolution, signal precision as RSD, limit of detection, limit of quantification, and accuracy as recovery) of both approaches were <4%, approximately 1, < or = 5%, <8 microM, 30 microM, between 91% and 104%, and <4%, < or = 2%, <9%, < or = 6 microM, < or = 20 microM (with the exception of protocatechuic acid, which shows values of 40 and 130 microM, respectively), between 80% and 107% for the CSEID and IAD concepts, respectively, which are excellent for food samples analysis. A set of representative samples was analyzed including apple and pear skins and pulps, red and white wines, and green tea tablets. High agreement was observed between the results of the sample analyses from the two microchip-based approaches, and good correlation was observed with results obtained from traditional methods. Although the prominent phenolic antioxidant classes and compounds were successfully determined, some nonprominent peaks were not detected in the samples when applying the IAD approach. Different integration strategies on microchip platforms were further explored, looking for a simplification of the overall analytical process without losing the excellent analytical characteristics obtained in both approaches. The results are promising and indicative of the progress of analytical microfluidics toward the "plateau of productivity" and the routine laboratory application.

Join our facebook page

The most complete medicinal herbs database backed by science

  • Works in 55 languages
  • Herbal cures backed by science
  • Herbs recognition by image
  • Interactive GPS map - tag herbs on location (coming soon)
  • Read scientific publications related to your search
  • Search medicinal herbs by their effects
  • Organize your interests and stay up do date with the news research, clinical trials and patents

Type a symptom or a disease and read about herbs that might help, type a herb and see diseases and symptoms it is used against.
*All information is based on published scientific research

Google Play badgeApp Store badge