English
Albanian
Arabic
Armenian
Azerbaijani
Belarusian
Bengali
Bosnian
Catalan
Czech
Danish
Deutsch
Dutch
English
Estonian
Finnish
Français
Greek
Haitian Creole
Hebrew
Hindi
Hungarian
Icelandic
Indonesian
Irish
Italian
Japanese
Korean
Latvian
Lithuanian
Macedonian
Mongolian
Norwegian
Persian
Polish
Portuguese
Romanian
Russian
Serbian
Slovak
Slovenian
Spanish
Swahili
Swedish
Turkish
Ukrainian
Vietnamese
Български
中文(简体)
中文(繁體)
Canadian Journal of Cardiology 1997-Jan

Feasibility and complications of single-plane and biplane versus multiplane transesophageal imaging: a review of 2947 consecutive studies.

Only registered users can translate articles
Log In/Sign up
The link is saved to the clipboard
J W Tam
I G Burwash
K J Ascah
M G Baird
K L Chan

Keywords

Abstract

OBJECTIVE

To analyze and compare the incidence of procedural complications and failure of intubation with various sizes of probes used in transesophageal echocardiography.

METHODS

Retrospective chart review.

METHODS

A Canadian, tertiary care hospital.

METHODS

A total of 2947 consecutive transesophageal echocardiographic patient examinations between January 1992 and March 1996 at the University of Ottawa Heart Institute, Ottawa, Ontario.

RESULTS

The multiplane probe (MP) was used in 1274 studies, biplane (BP) in 1642 and single plane (SP) in 31. Data for BP and SP were combined because of their similar size. Complications or failed intubation occurred in 86 studies (2.9%). There were 53 complications (1.8%) and 40 failed intubations (1.4%). Seven patients (0.3%) had both. Complications were death in one, tracheal intubation or bronchospasm in nine, bleeding in nine, angina in two, pulmonary edema in two, superficial thrombophlebitis in two, supraventricular tachycardia in one and minor adverse events in 27. Complications were unrelated to the choice of probe (MP 2%, BP and SP 1.7%, not significant). Failure of intubation (40 cases) was more common with MP than with BP and SP (2.3% versus 0.7%, P = 0.0003, OR 3.5, 95% CI 1.7 to 7.5). The main reasons for failure were cervical spondylosis in 16 patients and hypersensitive pharynx despite topical anesthesia and sedation in 13 patients. Of 21 cases of failed MP intubation, 16 (76%) were subsequently successful with BP.

CONCLUSIONS

Serious complications with transesophageal echocardiography, although infrequent, do occur. The MP carries a 3.5-fold increased risk of failed intubation. In the majority of failures, successful intubation can be achieved with a smaller probe.

Join our facebook page

The most complete medicinal herbs database backed by science

  • Works in 55 languages
  • Herbal cures backed by science
  • Herbs recognition by image
  • Interactive GPS map - tag herbs on location (coming soon)
  • Read scientific publications related to your search
  • Search medicinal herbs by their effects
  • Organize your interests and stay up do date with the news research, clinical trials and patents

Type a symptom or a disease and read about herbs that might help, type a herb and see diseases and symptoms it is used against.
*All information is based on published scientific research

Google Play badgeApp Store badge