English
Albanian
Arabic
Armenian
Azerbaijani
Belarusian
Bengali
Bosnian
Catalan
Czech
Danish
Deutsch
Dutch
English
Estonian
Finnish
Français
Greek
Haitian Creole
Hebrew
Hindi
Hungarian
Icelandic
Indonesian
Irish
Italian
Japanese
Korean
Latvian
Lithuanian
Macedonian
Mongolian
Norwegian
Persian
Polish
Portuguese
Romanian
Russian
Serbian
Slovak
Slovenian
Spanish
Swahili
Swedish
Turkish
Ukrainian
Vietnamese
Български
中文(简体)
中文(繁體)
Hernia : the journal of hernias and abdominal wall surgery 2008-Apr

Intraperitoneal modification of the Rives-Stoppa repair for large incisional hernias.

Only registered users can translate articles
Log In/Sign up
The link is saved to the clipboard
R F Williams
D F Martin
M T Mulrooney
G R Voeller

Keywords

Abstract

BACKGROUND

Recurrence rates for open repair of ventral/incisonal hernias historically range from 6% for the classic Rives-Stoppa repair to 35-45% for some of the techniques more commonly used in the United States. We report a modification to the classic Rives-Stoppa repair that allows intraperitoneal placement of the prosthetic, secured with a running suture. The abdominal muscles are closed over the mesh to protect it from any superficial wound problems that might develop and to restore normal architecture of the abdominal wall.

METHODS

A chart review was undertaken on all patients undergoing open ventral incisional hernia repair by a single surgeon from 2000 to 2006. All hernias were repaired with the intraperitoneal modification mimicking the principles of the Rives-Stoppa repair. Patient characteristics and operative and postoperative data were collected. Primary outcome was recurrence of hernia. Secondary outcomes were complications and rate of mesh infection.

RESULTS

One hundred and fifteen patients were evaluated. Thirty-four patients had repair of recurrent ventral hernias. The average patient was obese, female, and 59 years old. Twenty-five patients used tobacco, eleven were diabetic, and seven used chronic corticosteroids. Meshes utilized included ePTFE, coated polyester, coated polypropylene, and biologic mesh. Average size of mesh was 465.4 cm2. There were four recurrences (3.4%), three of which were due to mesh infection requiring mesh removal. Recurrence rate not secondary to mesh removal was 0.9%. Complications occurred in 26% with seroma formation being the most frequent (16%).

CONCLUSIONS

The intraperitoneal modification to the original Rives-Stoppa repair leads to a very low recurrence rate for large ventral hernia repairs with minimal complications and low rate of mesh infection.

Join our facebook page

The most complete medicinal herbs database backed by science

  • Works in 55 languages
  • Herbal cures backed by science
  • Herbs recognition by image
  • Interactive GPS map - tag herbs on location (coming soon)
  • Read scientific publications related to your search
  • Search medicinal herbs by their effects
  • Organize your interests and stay up do date with the news research, clinical trials and patents

Type a symptom or a disease and read about herbs that might help, type a herb and see diseases and symptoms it is used against.
*All information is based on published scientific research

Google Play badgeApp Store badge