English
Albanian
Arabic
Armenian
Azerbaijani
Belarusian
Bengali
Bosnian
Catalan
Czech
Danish
Deutsch
Dutch
English
Estonian
Finnish
Français
Greek
Haitian Creole
Hebrew
Hindi
Hungarian
Icelandic
Indonesian
Irish
Italian
Japanese
Korean
Latvian
Lithuanian
Macedonian
Mongolian
Norwegian
Persian
Polish
Portuguese
Romanian
Russian
Serbian
Slovak
Slovenian
Spanish
Swahili
Swedish
Turkish
Ukrainian
Vietnamese
Български
中文(简体)
中文(繁體)
Oman Journal of Ophthalmology 2009-Jan

Long-term variability in short-wavelength automated perimetry compared to standard perimetry in glaucoma patients and normal subjects.

Only registered users can translate articles
Log In/Sign up
The link is saved to the clipboard
Chintan Malhotra

Keywords

Abstract

OBJECTIVE

To compare long-term variability (LTV) in short-wavelength automated perimetry (SWAP) with that of standard white-on-white (W-W) perimetry, in primary open angle glaucoma (POAG) patients and normal subjects and to determine its clinical significance.

METHODS

The sample comprised 30 patients of stable POAG (group 1) and 20 age-matched normal controls (group2) who performed both SWAP and W-W perimetry thrice at monthly intervals. Long-term variability at each location in the visual field was calculated as the standard deviation of three threshold decibel values taken from the three visual fields performed. Mean LTV was then calculated for the entire field for each subgroup and compared.

RESULTS

Mean LTV in SWAP and W-W perimetry in glaucoma patients was 3.01 ± 0.74 dB and 2.73 ± 1.07dB respectively. In normal subjects mean LTV of SWAP and W-W perimetry was 2.69 ± 0.91 db and 1.97 ± 1.34 dB respectively. Intra group analysis revealed that mean LTV of SWAP was greater compared to W-W perimetry in normal subjects and glaucoma patients. In the latter, the difference did not reach statistical significance. Inter group analysis showed that mean LTV in both SWAP and W-W perimetry was greater in glaucoma patients than in normal subjects. Factors other than POAG that could influence LTV, including progression of cataract and change in pupil size due to use of pilocarpine were excluded. Mean examination time for SWAP per sitting was 7.65% longer than that for W-W perimetry.

CONCLUSIONS

Higher mean LTV of SWAP as compared to W-W perimetry needs to be taken into consideration when evaluating serial visual fields for change. Use of rapid threshold algorithms e.g. SITA (Swedish interactive test algorithm) SWAP should be encouraged as these will reduce the patient fatigue and increase the reliability of the test.

Join our facebook page

The most complete medicinal herbs database backed by science

  • Works in 55 languages
  • Herbal cures backed by science
  • Herbs recognition by image
  • Interactive GPS map - tag herbs on location (coming soon)
  • Read scientific publications related to your search
  • Search medicinal herbs by their effects
  • Organize your interests and stay up do date with the news research, clinical trials and patents

Type a symptom or a disease and read about herbs that might help, type a herb and see diseases and symptoms it is used against.
*All information is based on published scientific research

Google Play badgeApp Store badge