Lasers in Medical Science 2018-Aug

Dentinal tubule sealing effects of 532-nm diode-pumped solid-state laser, gallic acid/Fe3+ complex, and three commercial dentin desensitizers.

Solo los usuarios registrados pueden traducir artículos
Iniciar sesión Registrarse
El enlace se guarda en el portapapeles.
Soram Oh
Yu Gu
Hiran Perinpanayagam
Yeon-Jee Yoo
Yoon Lee
Ryun Kyung Kim
Seok Woo Chang
Jongho Lee
Qiang Zhu
Kee Yeon Kum

Palabras clave

Abstracto

The purpose of this study was to compare dentinal tubule sealing effects of a 532-nm diode-pumped solid-state (DPSS) laser, gallic acid/Fe3+ complex, and three commercially available dentin desensitizers. Human premolars (n = 44) extracted for orthodontics had standardized cervical cavities prepared, etched (37% phosphoric acid) and randomly assigned to either a control (n = 4), or one of five treatment groups (n = 8/group). Desensitizing treatments were either a 532-nm DPSS laser, gallic acid/Fe3+ complex, oxalate-based Super Seal™ (SS), DIO™ Enamel Coating Pen Pro Tooth (Dio), or adhesive-type Hybrid Coat™ (HC). Dentinal fluid flow (DFF) was monitored continuously in real time during the application of each desensitizing agent, by using a nanoliter-scaled fluid flow-measuring device. Following treatment, morphological changes on dentinal surfaces and within tubules were observed by scanning electron microscopy (SEM). DFF rates were significantly reduced after treatment in all experimental groups (P < 0.05), except SS (P > 0.05). The gallic acid/Fe3+ complex reduced DFF rates the most, and significantly (P < 0.05) more than the three commercial dentin desensitizers. There were no significant differences in DFF reduction rates between the gallic acid/Fe3+ complex and the DPSS laser groups (P > 0.05). There were no significant differences in DFF reduction rates among the three commercial dentin desensitizers (P > 0.05). SEM examination of treated dentin showed that the degree of occlusion of dentinal tubules correlated closely with the corresponding reduction in DFF rates. The gallic acid/Fe3+ complex and 532-nm DPSS laser were superior to other desensitizing methods in occluding dentinal tubules and reducing DFF rates.

Únete a nuestra
página de facebook

La base de datos de hierbas medicinales más completa respaldada por la ciencia

  • Funciona en 55 idiomas
  • Curas a base de hierbas respaldadas por la ciencia
  • Reconocimiento de hierbas por imagen
  • Mapa GPS interactivo: etiquete hierbas en la ubicación (próximamente)
  • Leer publicaciones científicas relacionadas con su búsqueda
  • Buscar hierbas medicinales por sus efectos.
  • Organice sus intereses y manténgase al día con las noticias de investigación, ensayos clínicos y patentes.

Escriba un síntoma o una enfermedad y lea acerca de las hierbas que podrían ayudar, escriba una hierba y vea las enfermedades y los síntomas contra los que se usa.
* Toda la información se basa en investigaciones científicas publicadas.

Google Play badgeApp Store badge