Spanish
Albanian
Arabic
Armenian
Azerbaijani
Belarusian
Bengali
Bosnian
Catalan
Czech
Danish
Deutsch
Dutch
English
Estonian
Finnish
Français
Greek
Haitian Creole
Hebrew
Hindi
Hungarian
Icelandic
Indonesian
Irish
Italian
Japanese
Korean
Latvian
Lithuanian
Macedonian
Mongolian
Norwegian
Persian
Polish
Portuguese
Romanian
Russian
Serbian
Slovak
Slovenian
Spanish
Swahili
Swedish
Turkish
Ukrainian
Vietnamese
Български
中文(简体)
中文(繁體)
Mutation Research - Fundamental and Molecular Mechanisms of Mutagenesis

Measurement of frequencies of HPRT mutants, chromosomal aberrations, micronuclei, sister-chromatid exchanges and cells with high frequencies of SCEs in styrene/dichloromethane-exposed workers.

Solo los usuarios registrados pueden traducir artículos
Iniciar sesión Registrarse
El enlace se guarda en el portapapeles.
A D Tates
T Grummt
F J van Dam
F de Zwart
F J Kasper
R Rothe
H Stirn
A H Zwinderman
A T Natarajan

Palabras clave

Abstracto

Frequencies of HPRT mutants (MFs), chromosomal aberrations with or without gaps (CA+; CA-), aberrant cells (AC), micronuclei (MN), sister-chromatid exchanges (SCEs) and cells with high frequencies of SCEs (HFCs) were measured in lymphocytes collected from 46 workers occupationally exposed to styrene and dichloromethane (DCM = methylene chloride). These parameters were also determined in 23 controls. Time-weighted average (TWA) values for styrene and DCM exposure during an 8-h working day were respectively 70 mg/m3 (range: 0-598) and 108 mg/m3 (range: 0-742). These values correspond to TWA values of 17 ppm styrene and 31 ppm DCM. In exposed workers, all cytogenetic parameters were significantly enhanced (P < 0.0001; one-sided), but, due to the lack of appropriate control data, no definite conclusions could be drawn concerning the mutagenicity of styrene/DCM exposure. Duration of exposure was not correlated with genetic effects analyzed. The TWA value for styrene was not correlated with the extent of genetic damage detected, but the TWA value for DCM was positively correlated with the frequencies of chromosome aberrations (with gaps) and aberrant cells. These observations make it difficult to decide whether styrene or DCM, or both chemicals, induced the cytogenetic effects observed in exposed workers. Using the present styrene/DCM data, earlier ethylene oxide data and unpublished epichlorohydrin data, the relative sensitivity of the genetic endpoints to detect genotoxic exposure was: HFC > CA- > CA+ > SCE > MN > HPRT.

Únete a nuestra
página de facebook

La base de datos de hierbas medicinales más completa respaldada por la ciencia

  • Funciona en 55 idiomas
  • Curas a base de hierbas respaldadas por la ciencia
  • Reconocimiento de hierbas por imagen
  • Mapa GPS interactivo: etiquete hierbas en la ubicación (próximamente)
  • Leer publicaciones científicas relacionadas con su búsqueda
  • Buscar hierbas medicinales por sus efectos.
  • Organice sus intereses y manténgase al día con las noticias de investigación, ensayos clínicos y patentes.

Escriba un síntoma o una enfermedad y lea acerca de las hierbas que podrían ayudar, escriba una hierba y vea las enfermedades y los síntomas contra los que se usa.
* Toda la información se basa en investigaciones científicas publicadas.

Google Play badgeApp Store badge