Spanish
Albanian
Arabic
Armenian
Azerbaijani
Belarusian
Bengali
Bosnian
Catalan
Czech
Danish
Deutsch
Dutch
English
Estonian
Finnish
Français
Greek
Haitian Creole
Hebrew
Hindi
Hungarian
Icelandic
Indonesian
Irish
Italian
Japanese
Korean
Latvian
Lithuanian
Macedonian
Mongolian
Norwegian
Persian
Polish
Portuguese
Romanian
Russian
Serbian
Slovak
Slovenian
Spanish
Swahili
Swedish
Turkish
Ukrainian
Vietnamese
Български
中文(简体)
中文(繁體)
Clinical Science 2002-Feb

Quantification of right-to-left shunt with (99m)Tc-labelled albumin macroaggregates and 100% oxygen in patients with hereditary haemorrhagic telangiectasia.

Solo los usuarios registrados pueden traducir artículos
Iniciar sesión Registrarse
El enlace se guarda en el portapapeles.
Johannes J Mager
Pieter Zanen
Fred Verzijlbergen
Cornelius J J Westermann
Tjeerd Haitjema
Gerard van Herk
Jan-Willem J Lammers

Palabras clave

Abstracto

Pulmonary arteriovenous malformations (PAVMs) are often associated with hereditary haemorrhagic telangiectasia (HHT). The quantification of right-to-left shunts in patients with PAVMs is important in diagnosis and follow up. Traditionally, this shunt is measured by the 100% oxygen method, in which the value for the arteriovenous difference in oxygen content, Cao(2)-CVO(2) (where Cao(2) is the oxygen content of arterial blood and CVO(2) is the oxygen content of mixed venous blood) is estimated. Alternative methods consist of measurement of the systemic or renal uptake of (99m)Tc-labelled macroaggregates of albumin (MAA), which are trapped in pulmonary capillaries, but pass through PAVMs. We first measured Cao(2)-CVO(2) in 12 HHT patients before and after embolization of PAVMs. We obtained a mean value of 4.4 ml/100 ml, instead of the usual 5 ml/100 ml. Subsequently, we measured right-to-left shunt in 21 HHT patients using the 100% oxygen method and with two different methods involving (99m)Tc. We used the kidney-lung method (K/L method), in which it is assumed that the right kidney receives 10% of the cardiac output, and we also used a method with two tracers (HSA/MAA method): (1) (99m)Tc-labelled human serum albumin (HSA) (which passes through pulmonary capillaries) to measure the fraction of the cardiac output perfusing the kidneys, and (2) MAA to measure the shunt fraction. In 35 shunt measurements we evaluated this new technique and the K/L method, by comparing the results with those from the 100% oxygen method. There was poor agreement between the 100% oxygen method and the K/L method, with 95% limits of agreement for the shunt fraction of -15.2% to +15.2%. There was moderate agreement between the 100% oxygen method and the HSA/MAA method, with limits of agreement of -8.3% to +7.7%. We conclude that the different methods cannot replace each other, because the limits of agreement are too wide for clinical use.

Únete a nuestra
página de facebook

La base de datos de hierbas medicinales más completa respaldada por la ciencia

  • Funciona en 55 idiomas
  • Curas a base de hierbas respaldadas por la ciencia
  • Reconocimiento de hierbas por imagen
  • Mapa GPS interactivo: etiquete hierbas en la ubicación (próximamente)
  • Leer publicaciones científicas relacionadas con su búsqueda
  • Buscar hierbas medicinales por sus efectos.
  • Organice sus intereses y manténgase al día con las noticias de investigación, ensayos clínicos y patentes.

Escriba un síntoma o una enfermedad y lea acerca de las hierbas que podrían ayudar, escriba una hierba y vea las enfermedades y los síntomas contra los que se usa.
* Toda la información se basa en investigaciones científicas publicadas.

Google Play badgeApp Store badge