Coronary Artery Disease 2001-Dec

Safety of ergot stress echocardiography for non-invasive detection of coronary vasospasm.

Solo los usuarios registrados pueden traducir artículos
Iniciar sesión Registrarse
El enlace se guarda en el portapapeles.
A Pálinkás
E Picano
O Rodriguez
A Diordjevic-Dikic
P Landi
A Varga
B Ghelarducci

Palabras clave

Abstracto

BACKGROUND

The safety of ergonovine/ergometrine stress testing for coronary vasospasm when performed outside the cardiac catheterization laboratory (cath lab) has been questioned vigorously.

OBJECTIVE

To assess the tolerability and safety of ergonovine/ergometrine stress testing performed in the echocardiographic laboratory (echo lab).

METHODS

We retrospectively reviewed the data prospectively collected in the echo lab of the Institute of Clinical Physiology from 1 January 1985 to 1 June 2000, from 587 tests performed on 573 patients (either ergonovine or ergometrine stress echocardiography testing). By selection, all patients had a history of chest pain, consistent with vasospastic angina, negative exercise stress testing or stress echocardiography (with dipyridamole, dobutamine or exercise), and normal or near normal resting left ventricular function. Ergonovine or ergometrine maleate was injected up to a total cumulative dosage of 0.35 mg, under continuous 12-lead electrocardiographic and two-dimensional echocardiographic monitoring.

RESULTS

There were no deaths, myocardial infarctions, ventricular fibrillations or third degree AV blocks. One patient had non-sustained ventricular tachycardia associated with transient ST segment elevation 30 min after the test. Three patients had second degree AV block associated with a positive echocardiography test that was promptly reversed by nitrates administration. Transient regional myocardial dysfunction occurred in 79 patients (13%). Limiting ischaemia-independent side effects were present in 17 patients (3%): hypotension in one, arterial hypertension in five, non-sustained ventricular tachycardia in two and nausea or vomiting in ten. The test was well tolerated and echocardiograms were interpretable in 97% of the tests performed.

CONCLUSIONS

Pharmacological stress echocardiography with either ergonovine or ergometrine is well tolerated and can be performed with relatively low risk in the echo lab in properly selected patients in whom coronary vasospasm is suspected.

Únete a nuestra
página de facebook

La base de datos de hierbas medicinales más completa respaldada por la ciencia

  • Funciona en 55 idiomas
  • Curas a base de hierbas respaldadas por la ciencia
  • Reconocimiento de hierbas por imagen
  • Mapa GPS interactivo: etiquete hierbas en la ubicación (próximamente)
  • Leer publicaciones científicas relacionadas con su búsqueda
  • Buscar hierbas medicinales por sus efectos.
  • Organice sus intereses y manténgase al día con las noticias de investigación, ensayos clínicos y patentes.

Escriba un síntoma o una enfermedad y lea acerca de las hierbas que podrían ayudar, escriba una hierba y vea las enfermedades y los síntomas contra los que se usa.
* Toda la información se basa en investigaciones científicas publicadas.

Google Play badgeApp Store badge