International journal of cardiac imaging 1999-Aug

Stroke volume changes during dobutamine-atropine stress echocardiography: the influence of heart rate and ischaemia.

Solo los usuarios registrados pueden traducir artículos
Iniciar sesión Registrarse
El enlace se guarda en el portapapeles.
D Poldermans
R Rambaldi
E Boersma
W Vletter
S Carlier
A Elhendy
J J Bax
A J Man in 't Veld
J R Roelandt

Palabras clave

Abstracto

BACKGROUND

A decrease in stroke volume during dobutamine-atropine stress echocardiography heralds ischaemia and possible hypotension. Hypotension results from worsening of LV-function (as a result of ischaemia) left ventricular outflow tract obstruction or hypovolemia, while an increase of stroke volume indicates the preservation of myocardial contractile reserve.

OBJECTIVE

To assess stroke volume changes during dobutamine stress echocardiography in relation to heart rate and occurrence of ischaemia and to validate a new automated cardiac output measurement device.

METHODS

In fifty patients, the stroke volume was assessed using the echocardiographic biplane discs method during a stress echocardiography. These data were reference values for the validation of a new automated cardiac output measurement using the first method as a reference.

RESULTS

Stroke volume measured by the biplane discs method and automated cardiac output device decreased from rest to peak stress, respectively, from 54+/-16 to 34+/-9 (63%) ml and 63+/-17 to 38+/-15 (60%) ml (p < 0.001). Stroke volume decreased with increased heart rate and stress-induced ischaemia when assessed by the biplane discs method, but with the automated device it decreased only with increased heart rate.

CONCLUSIONS

Both increased heart rate and myocardial ischaemia during dobutamine stress echocardiography cause a reduction of stroke volume. However, the automated device did not detect the effects of stress-induced ischaemia on stroke volume. It appears that the biplane discs method is more sensitive for evaluating the effect of ischaemia.

Únete a nuestra
página de facebook

La base de datos de hierbas medicinales más completa respaldada por la ciencia

  • Funciona en 55 idiomas
  • Curas a base de hierbas respaldadas por la ciencia
  • Reconocimiento de hierbas por imagen
  • Mapa GPS interactivo: etiquete hierbas en la ubicación (próximamente)
  • Leer publicaciones científicas relacionadas con su búsqueda
  • Buscar hierbas medicinales por sus efectos.
  • Organice sus intereses y manténgase al día con las noticias de investigación, ensayos clínicos y patentes.

Escriba un síntoma o una enfermedad y lea acerca de las hierbas que podrían ayudar, escriba una hierba y vea las enfermedades y los síntomas contra los que se usa.
* Toda la información se basa en investigaciones científicas publicadas.

Google Play badgeApp Store badge