Journal of Invasive Cardiology 2017-Sep

Transfemoral Transcatheter Aortic Valve-in-Valve Implantation for Aortic Valve Bioprosthesis Failure With the Fully Repositionable and Retrievable Lotus Valve: A Single-Center Experience.

Solo los usuarios registrados pueden traducir artículos
Iniciar sesión Registrarse
El enlace se guarda en el portapapeles.
Neil Ruparelia
Katharine Thomas
James D Newton
Kate Grebenik
Amar Keiralla
George Krasopoulos
Rana Sayeed
Adrian P Banning
Rajesh K Kharbanda

Palabras clave

Abstracto

OBJECTIVE

To report a first case series of the Lotus valve (Boston Scientific) for the treatment of surgical aortic bioprosthesis failure.

BACKGROUND

Valve-in-valve (VIV) transcatheter aortic valve implantation (TAVI) is an established management option for surgical aortic bioprosthesis failure. Although TAVI has proven efficacious, complications relating to suboptimal valve implantation have been reported in approximately 5% of patients. The Lotus valve is fully repositionable and retrievable, and therefore enables complete assessment of valve function prior to definitive deployment. However, data supporting its use for this indication are limited.

METHODS

Consecutive patients who underwent transfemoral VIV-TAVI at John Radcliffe Hospital between January 2015 and December 2016 were retrospectively analyzed. Procedural and 30-day outcomes were reported in accordance with Valve Academic Research Consortium-2 (VARC-2) definitions.

RESULTS

Seven patients underwent VIV-TAVI with the Lotus valve. Device success according to VARC-2 criteria was achieved in 6 of the 7 patients. Following implantation, transvalvular hemodynamics were acceptable, with a mean gradient of 11.9 ± 6.6 mm Hg. All patients had mild or no residual aortic regurgitation. Specifically, no patient required further valve-related intervention, or suffered myocardial infarction, stroke, or acute kidney injury stage 2 or 3. There were no deaths during the follow-up period.

CONCLUSIONS

Transfemoral VIV-TAVI for the treatment of surgical aortic bioprosthesis failure with the Lotus device appears to be safe and is associated with no significant residual aortic regurgitation, and offers favorable transvalvular hemodynamics at 30-day follow-up.

Únete a nuestra
página de facebook

La base de datos de hierbas medicinales más completa respaldada por la ciencia

  • Funciona en 55 idiomas
  • Curas a base de hierbas respaldadas por la ciencia
  • Reconocimiento de hierbas por imagen
  • Mapa GPS interactivo: etiquete hierbas en la ubicación (próximamente)
  • Leer publicaciones científicas relacionadas con su búsqueda
  • Buscar hierbas medicinales por sus efectos.
  • Organice sus intereses y manténgase al día con las noticias de investigación, ensayos clínicos y patentes.

Escriba un síntoma o una enfermedad y lea acerca de las hierbas que podrían ayudar, escriba una hierba y vea las enfermedades y los síntomas contra los que se usa.
* Toda la información se basa en investigaciones científicas publicadas.

Google Play badgeApp Store badge