American Journal of Roentgenology 2015-Jan

Utility of ⁹⁹mTc-human serum albumin diethylenetriamine pentaacetic acid SPECT for evaluating endoleak after endovascular abdominal aortic aneurysm repair.

Solo los usuarios registrados pueden traducir artículos
Iniciar sesión Registrarse
El enlace se guarda en el portapapeles.
Motoki Nakai
Hirotatsu Sato
Morio Sato
Akira Ikoma
Tetsuo Sonomura
Yoshiharu Nishimura
Yoshitaka Okamura

Palabras clave

Abstracto

OBJECTIVE

The purpose of this study was to assess the utility of (99m)Tc-human serum albumin diethylenetriamine pentaacetic acid ((99m)Tc-HSAD) SPECT in the detection of endoleaks after endovascular abdominal aortic aneurysm repair.

METHODS

Fifteen patients (11 men, four women) with aneurysm sac expansion of 5 mm or greater after endovascular abdominal aortic aneurysm repair underwent three-phase CT, (99m)Tc-HSAD SPECT, and CT during aortography. Sensitivity calculations for three-phase CT and (99m)Tc-HSAD SPECT were performed with CT during aortography as the reference standard. The volume of each endoleak was measured with CT during aortography. Seven subjects underwent embolization with N-butyl cyanoacrylate (NBCA)-Lipiodol (ethiodized oil, Guerbet and metallic coils. Three-phase CT and (99m)Tc-HSAD SPECT were repeated after embolization to assess their efficacy.

RESULTS

Endoleaks were interpreted as perigraft radioisotope accumulation in 12 patients (80.0%) on (99m)Tc-HSAD SPECT images, in 13 patients (86.7%) on three-phase CT images, and in 15 patients (100%) on CT during aortography. The mean endoleak volume visualized with (99m)Tc-HSAD SPECT was 8.37 cm(3) (range, 5.2-15.1 cm(3)), and the volume not visualized was 3.47 cm(3) (2.5-4.6 cm(3)), a statistically significant difference (p = 0.019). In two patients, (99m)Tc-HSAD SPECT depicted endoleaks evident at delayed phase CT during aortography but not at three-phase CT, suggesting they were slow-filling endoleaks. Accumulation of (99m)Tc-HSAD corresponding to endoleaks disappeared after embolization, but CT evaluation of embolization was impeded by artifacts of NBCA-Lipiodol and metallic coils.

CONCLUSIONS

Technetium-99m-labeled HSAD SPECT proved less sensitive than three-phase CT but depicted endoleaks with volumes 5.2 cm(3) or greater as perigraft radioisotope accumulation. Slow-filling endoleaks can be visualized with (99m)Tc-HSAD SPECT, which can be used to evaluate the efficacy of embolization.

Únete a nuestra
página de facebook

La base de datos de hierbas medicinales más completa respaldada por la ciencia

  • Funciona en 55 idiomas
  • Curas a base de hierbas respaldadas por la ciencia
  • Reconocimiento de hierbas por imagen
  • Mapa GPS interactivo: etiquete hierbas en la ubicación (próximamente)
  • Leer publicaciones científicas relacionadas con su búsqueda
  • Buscar hierbas medicinales por sus efectos.
  • Organice sus intereses y manténgase al día con las noticias de investigación, ensayos clínicos y patentes.

Escriba un síntoma o una enfermedad y lea acerca de las hierbas que podrían ayudar, escriba una hierba y vea las enfermedades y los síntomas contra los que se usa.
* Toda la información se basa en investigaciones científicas publicadas.

Google Play badgeApp Store badge