Chest 2016-Sep

Computer-Aided Quantitative Ultrasonography for Detection of Pulmonary Edema in Mechanically Ventilated Cardiac Surgery Patients.

Ainult registreeritud kasutajad saavad artikleid tõlkida
Logi sisse
Link salvestatakse lõikelauale
Francesco Corradi
Claudia Brusasco
Antonella Vezzani
Gregorio Santori
Tullio Manca
Lorenzo Ball
Francesco Nicolini
Tiziano Gherli
Vito Brusasco

Märksõnad

Abstraktne

BACKGROUND

Lung ultrasonography (LUS) has been used for noninvasive detection of pulmonary edema. Semiquantitative LUS visual scores (visual LUS [V-LUS]) based on B lines are moderately correlated with pulmonary capillary wedge pressure (PCWP) and extravascular lung water (EVLW). A new computer-aided quantitative LUS (Q-LUS) analysis has been recently proposed. This study investigated whether Q-LUS better correlates with PCWP and EVLW than V-LUS and to what extent positive end-expiratory pressure (PEEP) affects the assessment of pulmonary edema by Q-LUS or V-LUS.

METHODS

Forty-eight mechanically ventilated patients with PEEP of 5 or 10 cm H2O and monitored by PCWP (n = 28) or EVLW (n = 20) were studied.

RESULTS

PCWP was significantly and strongly correlated with Q-LUS gray (Gy) unit value (r(2) = 0.70) but weakly correlated with V-LUS B-line score (r(2) = 0.20). EVLW was significantly and more strongly correlated with Q-LUS Gy unit mean value (r(2) = 0.68) than with V-LUS B-line score (r(2) = 0.34). Q-LUS showed a better diagnostic accuracy than V-LUS for the detection of PCWP >18 mm Hg or EVLW ≥ 10 mL/kg. With 5-cm H2O PEEP, the correlations with PCWP or EVLW were stronger for Q-LUS than V-LUS. With 10-cm H2O PEEP, the correlations with PCWP or EVLW were still significant for Q-LUS but insignificant for V-LUS. Interobserver reproducibility was better for Q-LUS than V-LUS.

CONCLUSIONS

Both V-LUS and Q-LUS are acceptable indicators of pulmonary edema in mechanically ventilated patients. However, at high PEEP only Q-LUS provides data that are significantly correlated with PCWP and EVLW. Computer-aided Q-LUS has the advantages of being not only independent of operator perception but also of PEEP.

Liitu meie
facebooki lehega

Kõige täiuslikum ravimtaimede andmebaas, mida toetab teadus

  • Töötab 55 keeles
  • Taimsed ravimid, mida toetab teadus
  • Maitsetaimede äratundmine pildi järgi
  • Interaktiivne GPS-kaart - märgistage ürdid asukohas (varsti)
  • Lugege oma otsinguga seotud teaduspublikatsioone
  • Otsige ravimtaimi nende mõju järgi
  • Korraldage oma huvisid ja hoidke end kursis uudisteuuringute, kliiniliste uuringute ja patentidega

Sisestage sümptom või haigus ja lugege ravimtaimede kohta, mis võivad aidata, tippige ürdi ja vaadake haigusi ja sümptomeid, mille vastu seda kasutatakse.
* Kogu teave põhineb avaldatud teaduslikel uuringutel

Google Play badgeApp Store badge