Estonian
Albanian
Arabic
Armenian
Azerbaijani
Belarusian
Bengali
Bosnian
Catalan
Czech
Danish
Deutsch
Dutch
English
Estonian
Finnish
Français
Greek
Haitian Creole
Hebrew
Hindi
Hungarian
Icelandic
Indonesian
Irish
Italian
Japanese
Korean
Latvian
Lithuanian
Macedonian
Mongolian
Norwegian
Persian
Polish
Portuguese
Romanian
Russian
Serbian
Slovak
Slovenian
Spanish
Swahili
Swedish
Turkish
Ukrainian
Vietnamese
Български
中文(简体)
中文(繁體)
International Ophthalmology 2014-Aug

Postoperative refractive error following cataract surgery after the first attack of acute primary angle closure.

Ainult registreeritud kasutajad saavad artikleid tõlkida
Logi sisse
Link salvestatakse lõikelauale
Tadayuki Nishide
Natsuki Hayakawa
Ikuko Kimura
Misako Nakanishi
Yoko Yagi
Etsuko Shibuya
Nobuhisa Mizuki

Märksõnad

Abstraktne

To investigate differences between preoperative target refraction and postoperative spherical equivalent refraction in eyes with the first attack of acute angle closure glaucoma before and after surgery. We retrospectively examined eyes of 36 patients who suffered the first attack of acute primary angle closure after undergoing cataract extraction and intraocular lens implant. We measured keratometric values (K1, K2) due to medical therapy for high ocular tension and the mean time interval until surgery. We compared the axial length, expected diopter, logMAR visual acuity, K1, K2, refractive spherical equivalent, and intraocular pressure (IOP) before and 6 months after surgery. The average preoperative IOP was 51.3 ± 9.0 mmHg, but it decreased to 14.8 ± 3.6 mmHg after surgery. No corneal edema was observed after surgery. The average axial length was 22.12 ± 1.03 mm and there was no significant change in keratometric values, which were 7.72 ± 0.33 mm (K1) and 7.51 ± 0.31 mm (K2) before surgery and 7.67 ± 0.33 mm (K1) and 7.49 ± 0.29 mm (K2) after surgery. Similarly, no significant difference was observed in average preoperative target refractive error (-0.57 ± 0.53 D) and average postoperative refractive spherical equivalent (-0.67 ± 0.97 D). The inability to accurately determine preoperative refractive error due to corneal edema or other complications is a concern during the first attack of acute angle closure glaucoma. However, our results indicate that no differences should be expected between preoperative refractive error and postoperative refractive spherical equivalent.

Liitu meie
facebooki lehega

Kõige täiuslikum ravimtaimede andmebaas, mida toetab teadus

  • Töötab 55 keeles
  • Taimsed ravimid, mida toetab teadus
  • Maitsetaimede äratundmine pildi järgi
  • Interaktiivne GPS-kaart - märgistage ürdid asukohas (varsti)
  • Lugege oma otsinguga seotud teaduspublikatsioone
  • Otsige ravimtaimi nende mõju järgi
  • Korraldage oma huvisid ja hoidke end kursis uudisteuuringute, kliiniliste uuringute ja patentidega

Sisestage sümptom või haigus ja lugege ravimtaimede kohta, mis võivad aidata, tippige ürdi ja vaadake haigusi ja sümptomeid, mille vastu seda kasutatakse.
* Kogu teave põhineb avaldatud teaduslikel uuringutel

Google Play badgeApp Store badge