Estonian
Albanian
Arabic
Armenian
Azerbaijani
Belarusian
Bengali
Bosnian
Catalan
Czech
Danish
Deutsch
Dutch
English
Estonian
Finnish
Français
Greek
Haitian Creole
Hebrew
Hindi
Hungarian
Icelandic
Indonesian
Irish
Italian
Japanese
Korean
Latvian
Lithuanian
Macedonian
Mongolian
Norwegian
Persian
Polish
Portuguese
Romanian
Russian
Serbian
Slovak
Slovenian
Spanish
Swahili
Swedish
Turkish
Ukrainian
Vietnamese
Български
中文(简体)
中文(繁體)
Surgery 1999-11

Reproducibility of lymphoscintigraphic drainage patterns in sequential 99mTc human serum albumin and 99mTc sulfur colloid studies: implications for sentinel node identification in melanoma.

Ainult registreeritud kasutajad saavad artikleid tõlkida
Logi sisse
Link salvestatakse lõikelauale
A Tonakie
V Sondak
A Yahanda
R L Wahl

Märksõnad

Abstraktne

Selective lymphadenectomy, based on prior lymphatic mapping and sentinel node identification and excision, is now the standard management for intermediate-thickness melanomas in many cancer centers worldwide. At our center 99m-labeled technetium human serum albumin (HSA) scans are performed before the day of surgery in some patients with truncal lesions to detect multiple sites of lymphatic drainage. 99mTc sulfur colloid (SC) is then injected before the operation to delineate the sentinel node(s) for gamma-probe-guided excision. Our purpose was to retrospectively evaluate whether comparable diagnostic information resulted from lymphoscintigraphy performed with these 2 different agents.

All patients with melanoma who had dual sequential 99mTc HSA and 99mTc SC studies between January 1, 1996, and December 31, 1997, were reviewed.

Thirty-eight patients underwent paired HSA and SC imaging. Thirty-two patients had concordant scan findings. In all 6 discordant studies, 2 separate drainage areas were defined by HSA, but only 1 drainage area was defined by SC.

In 15.8% of dual studies (6/38 studies), discordant imaging results were obtained between HSA and SC. SC studies alone may result in nonvisualization of at-risk draining lymph node beds and hence failure to identify and excise all sentinel nodes. This could result in inaccurate staging, inappropriate therapy, and altered prognosis. A reduction in SC dose from 3 to 1 mCi was probably the most significant causal factor leading to these discrepancies, which suggests that the 3-mCi dose is preferable.

Liitu meie
facebooki lehega

Kõige täiuslikum ravimtaimede andmebaas, mida toetab teadus

  • Töötab 55 keeles
  • Taimsed ravimid, mida toetab teadus
  • Maitsetaimede äratundmine pildi järgi
  • Interaktiivne GPS-kaart - märgistage ürdid asukohas (varsti)
  • Lugege oma otsinguga seotud teaduspublikatsioone
  • Otsige ravimtaimi nende mõju järgi
  • Korraldage oma huvisid ja hoidke end kursis uudisteuuringute, kliiniliste uuringute ja patentidega

Sisestage sümptom või haigus ja lugege ravimtaimede kohta, mis võivad aidata, tippige ürdi ja vaadake haigusi ja sümptomeid, mille vastu seda kasutatakse.
* Kogu teave põhineb avaldatud teaduslikel uuringutel

Google Play badgeApp Store badge