Estonian
Albanian
Arabic
Armenian
Azerbaijani
Belarusian
Bengali
Bosnian
Catalan
Czech
Danish
Deutsch
Dutch
English
Estonian
Finnish
Français
Greek
Haitian Creole
Hebrew
Hindi
Hungarian
Icelandic
Indonesian
Irish
Italian
Japanese
Korean
Latvian
Lithuanian
Macedonian
Mongolian
Norwegian
Persian
Polish
Portuguese
Romanian
Russian
Serbian
Slovak
Slovenian
Spanish
Swahili
Swedish
Turkish
Ukrainian
Vietnamese
Български
中文(简体)
中文(繁體)
Journal of Burn Care and Research

The reliability and concurrent validity of the figure-of-eight method of measuring hand edema in patients with burns.

Ainult registreeritud kasutajad saavad artikleid tõlkida
Logi sisse
Link salvestatakse lõikelauale
William S Dewey
Travis L Hedman
Ted T Chapman
Steven E Wolf
John B Holcomb

Märksõnad

Abstraktne

OBJECTIVE

Water volumetry is considered the "gold standard" for hand edema assessment. This technique requires considerable time, staff, and specialized equipment. The figure-of-eight method for hand edema assessment has been tested only in the orthopedic population. The objective of this study was to test the reliability and concurrent validity of the figure-of-eight method of measuring hand edema in the burn patient population.

METHODS

We conducted a prospective blinded study with 20 burned patients (33 edematous hands) admitted from February to May 2005. Two testers performed three separate blinded measurements on each edematous hand, using the figure-of-eight technique. A third tester performed two measurements, using water volumetry. An independent investigator recorded all measurements. Intratester and intertester reliability were analyzed. Concurrent validity was examined and compared with water volumetry measurements.

RESULTS

Intraclass correlation coefficients (ICC) for the intratester reliability of the figure-of-eight method were 0.96 for tester 1 and 0.97 for tester 2. The ICC for intertester reliability of the figure-of-eight measurements was 0.94. The intratester ICC for volumetric measurements was 0.99. Correlation coefficient (Pearson's) for tester 1 was 0.83 (P < .01), and for tester 2, 0.89 (P < .01).

CONCLUSIONS

The figure-of-eight technique is a reliable and valid measurement tool for measuring hand edema. This technique is a more clinically feasible tool than water volumetry in the burn patient population.

Liitu meie
facebooki lehega

Kõige täiuslikum ravimtaimede andmebaas, mida toetab teadus

  • Töötab 55 keeles
  • Taimsed ravimid, mida toetab teadus
  • Maitsetaimede äratundmine pildi järgi
  • Interaktiivne GPS-kaart - märgistage ürdid asukohas (varsti)
  • Lugege oma otsinguga seotud teaduspublikatsioone
  • Otsige ravimtaimi nende mõju järgi
  • Korraldage oma huvisid ja hoidke end kursis uudisteuuringute, kliiniliste uuringute ja patentidega

Sisestage sümptom või haigus ja lugege ravimtaimede kohta, mis võivad aidata, tippige ürdi ja vaadake haigusi ja sümptomeid, mille vastu seda kasutatakse.
* Kogu teave põhineb avaldatud teaduslikel uuringutel

Google Play badgeApp Store badge