Treatment of blister-like aneurysms with the pipeline embolization device.
Märksõnad
Abstraktne
BACKGROUND
Endovascular vessel reconstruction with the pipeline embolization device (PED) has become common practice. Data on the safety and efficacy of the PED in blister-like aneurysms (BLAs) are limited.
OBJECTIVE
To retrospectively present our experience with use of the PED in BLAs.
METHODS
A total of 8 patients harboring 8 BLAs were treated with the PED at our institution between November 2011 and April 2013.
RESULTS
Aneurysm size was 2.5 mm on average. Five patients had sustained a subarachnoid hemorrhage (SAH), 1 patient presented with sentinel headaches, and in 2 patients the aneurysm was incidentally discovered. Seven aneurysms arose from the ICA and 1 from the basilar artery. Placement of the PED was successful in all 8 patients. There were no procedural or perioperative complications in any of the patients. At the latest follow-up, all 8 patients achieved a favorable outcome (mRS 0-2). Angiographic follow-up was available for 6 patients at a mean time point of 3.9 months. Follow-up angiography showed 100% aneurysm occlusion in 5 patients and marked decrease in aneurysm size in 1 patient.
CONCLUSIONS
The findings of this study suggest that the PED may be a safe and effective treatment for BLAs. Given the limitations of other treatment modalities and the challenging nature of BLAs, flow diversion may be a valuable option for these lesions.