Veterinary Clinical Pathology 2010-Sep

Tyrosine-derived 4-hydroxyphenylpyruvate reacts with ketone test fields of 3 commercially available urine dipsticks.

Ainult registreeritud kasutajad saavad artikleid tõlkida
Logi sisse
Link salvestatakse lõikelauale
James Cartwright
Richard M Green

Märksõnad

Abstraktne

BACKGROUND

The enzyme 4-hydroxyphenylpyruvate dioxygenase (HPPD) is key in tyrosine catabolism. Inhibition of HPPD results in tyrosinemia and increased urinary excretion of 3 phenylketones: 4-hydroxyphenylpyruvate (HPPA), 4-hydroxyphenyllactate (HPLA), and 4-hydroxyphenylacetate (HPAA). A previous study involving administration of a novel HPPD inhibitor to dogs resulted in detection of ketonuria in treated animals using urine dipsticks read by reflectance photometry. Dipstick-positive results were suspected to be false because high concentrations of urinary phenylketones have been reported to react with ketone test fields of urine dipsticks, but visual confirmation was not performed.

OBJECTIVE

The purpose of this study was to determine which of the 4- hydroxyphenolic acids produced by HPPD inhibition react with ketone test fields of 3 commercially available urine dipsticks.

METHODS

Canine urine samples were prepared with HPPA, HPLA, HPAA, and lithium acetoacetate (positive control) at 6 concentrations. Unmodified urine samples were used as negative controls. All samples were tested for ketones using Combur 10 Test M dipsticks read by a Miditron dipstick analyzer. Urinalysis was also performed by visually inspecting ketone test fields on the Combur 10 Test M, Multistix 10 SG, and Aution 10 EA dipsticks.

RESULTS

Urine samples containing HPPA were positive for ketones with Combur 10 Test M dipsticks read by the Miditron analyzer and produced a red–brown color change in ketone test fields of all 3 dipsticks. Urine samples containing HPLA and HPAA were negative by all methods.

CONCLUSIONS

The phenylketone HPPA reacts with ketone test fields of 3 commercially available urine dipsticks, producing a red–brown color change that may be misinterpreted as positive for ketones by reflectance photometry.

Liitu meie
facebooki lehega

Kõige täiuslikum ravimtaimede andmebaas, mida toetab teadus

  • Töötab 55 keeles
  • Taimsed ravimid, mida toetab teadus
  • Maitsetaimede äratundmine pildi järgi
  • Interaktiivne GPS-kaart - märgistage ürdid asukohas (varsti)
  • Lugege oma otsinguga seotud teaduspublikatsioone
  • Otsige ravimtaimi nende mõju järgi
  • Korraldage oma huvisid ja hoidke end kursis uudisteuuringute, kliiniliste uuringute ja patentidega

Sisestage sümptom või haigus ja lugege ravimtaimede kohta, mis võivad aidata, tippige ürdi ja vaadake haigusi ja sümptomeid, mille vastu seda kasutatakse.
* Kogu teave põhineb avaldatud teaduslikel uuringutel

Google Play badgeApp Store badge