Persian
Albanian
Arabic
Armenian
Azerbaijani
Belarusian
Bengali
Bosnian
Catalan
Czech
Danish
Deutsch
Dutch
English
Estonian
Finnish
Français
Greek
Haitian Creole
Hebrew
Hindi
Hungarian
Icelandic
Indonesian
Irish
Italian
Japanese
Korean
Latvian
Lithuanian
Macedonian
Mongolian
Norwegian
Persian
Polish
Portuguese
Romanian
Russian
Serbian
Slovak
Slovenian
Spanish
Swahili
Swedish
Turkish
Ukrainian
Vietnamese
Български
中文(简体)
中文(繁體)
Annals of Vascular Surgery 2016-Apr

Comparison of Nonpenetrating Titanium Clips versus Continuous Polypropylene Suture in Dialysis Access Creation.

فقط کاربران ثبت نام شده می توانند مقالات را ترجمه کنند
ورود به سیستم / ثبت نام
پیوند در کلیپ بورد ذخیره می شود
Khanh P Nguyen
Theodore Teruya
Olamide Alabi
Neha Sheng
Christian Bianchi
Jason Chiriano
Salem Dehom
Ahmed Abou-Zamzam

کلید واژه ها

خلاصه

BACKGROUND

Nonpenetrating titanium surgical clips (clips) offer a theoretical advantage of inducing less intimal hyperplasia at an anastomosis because of less endothelial injury. Whether this translates into improved outcomes when used in the creation of arteriovenous fistulas (AVFs) remains unclear. We sought to compare the maturation, patency, and failure rates of anastomoses created using traditional continuous polypropylene suture and clips.

METHODS

All primary AVF created at a single Veterans Administration Medical Center were reviewed over a 6-year period. Anastomoses were created with either clips or suture based on surgeon preference. Patient characteristics and surgical outcomes were collected. Comparisons were made between the 2 groups.

RESULTS

Over a 6-year period, 334 fistulas were created (29% suture and 71% clips) in 326 patients. The mean age was 64.8 ± 11 years with 98% males. Comorbidities included diabetes (70%), hypertension (96.1%), and tobacco use (52.9% previous or current). Approximately half the patients were predialysis. Comparison of patient characteristics showed no differences between the suture and clip groups. There was no significant difference in maturation rate (suture 79% versus clips 72%, P = 0.25), median time to maturation (suture 62 ± 35 versus clips 71 ± 13 days, P = 0.07), 1 year primary patency rate (suture 37.4% versus clips 39.6, P = 0.72), 1 year assisted primary patency rate (suture 82.4% versus clips 76.3%, P = 0.31), or overall failure rates (suture 62% versus clips 58%, P = 0.56). Median time to initial failure or reintervention was not significantly different in the clip group (suture 615 [range, 239-991] versus clips 812 [range, 635-989] days, P = 0.72).

CONCLUSIONS

Compared to traditional polypropylene suture creation of upper extremity AVFs, nonpenetrating clips had equivalent maturation, 1-year patency, and overall failure rates. Neither clips nor suture offers any clear advantage in the creation of AVF.

به صفحه فیس بوک ما بپیوندید

کاملترین پایگاه داده گیاهان دارویی با پشتیبانی علمی

  • به 55 زبان کار می کند
  • درمان های گیاهی با پشتوانه علم
  • شناسایی گیاهان توسط تصویر
  • نقشه GPS تعاملی - گیاهان را در مکان نشان دهید (به زودی)
  • انتشارات علمی مربوط به جستجوی خود را بخوانید
  • گیاهان دارویی را با توجه به اثرات آنها جستجو کنید
  • علایق خود را سازماندهی کنید و با تحقیقات اخبار ، آزمایشات بالینی و حق ثبت اختراع در جریان باشید

علامت یا بیماری را تایپ کنید و در مورد گیاهانی که ممکن است به شما کمک کنند ، بخوانید ، یک گیاه تایپ کنید و بیماری ها و علائمی را که در برابر آن استفاده می شود ، ببینید.
* کلیه اطلاعات براساس تحقیقات علمی منتشر شده است

Google Play badgeApp Store badge