Journal of Biomedical Optics

Noninvasive method for measuring local hemoglobin oxygen saturation in tissue using wide gap second derivative near-infrared spectroscopy.

فقط کاربران ثبت نام شده می توانند مقالات را ترجمه کنند
ورود به سیستم / ثبت نام
پیوند در کلیپ بورد ذخیره می شود
Dean E Myers
LeAnn D Anderson
Roxanne P Seifert
Joseph P Ortner
Chris E Cooper
Greg J Beilman
John D Mowlem

کلید واژه ها

خلاصه

A simple continuous wave near-infrared algorithm for estimating local hemoglobin oxygen saturation in tissue (%StO2) is described using single depth attenuation measurements at 680, 720, 760, and 800 nm. Second derivative spectroscopy was used to reduce light scattering effects, chromophores with constant absorption, baseline/instrumentation drift, and movement artifacts. Unlike previous second derivative methods which focused primarily on measuring deoxyhemoglobin concentration; a wide 40 nm wavelength gap used for calculating second derivative attenuation significantly improved sensitivity to oxyhemoglobin absorption. Scaled second derivative attenuation at 720 nm was correlated to in vitro hemoglobin oxygen saturation to generate a %StO2 calibration curve. The calibration curve was insensitive to total hemoglobin, optical path length, and optical scattering. Measurement error due to normal levels of carboxyhemoglobin, methemoglobin, and water absorption were less than 10 %StO2 units. Severe methemoglobinemia or edema combined with low blood volume could cause StO2 errors to exceed 10 StO2 units. Both a broadband and commercial four-wavelength spectrometer (InSpectra) measured %StO2. The InSpectra tissue spectrometer readily detected limb ischemia on 26 human volunteers for hand, forearm, and leg muscles. A strong linear correlation, r2>0.93, between StO2 and microvascular %SO2 was observed for isolated animal hind limb, kidney, and heart.

به صفحه فیس بوک ما بپیوندید

کاملترین پایگاه داده گیاهان دارویی با پشتیبانی علمی

  • به 55 زبان کار می کند
  • درمان های گیاهی با پشتوانه علم
  • شناسایی گیاهان توسط تصویر
  • نقشه GPS تعاملی - گیاهان را در مکان نشان دهید (به زودی)
  • انتشارات علمی مربوط به جستجوی خود را بخوانید
  • گیاهان دارویی را با توجه به اثرات آنها جستجو کنید
  • علایق خود را سازماندهی کنید و با تحقیقات اخبار ، آزمایشات بالینی و حق ثبت اختراع در جریان باشید

علامت یا بیماری را تایپ کنید و در مورد گیاهانی که ممکن است به شما کمک کنند ، بخوانید ، یک گیاه تایپ کنید و بیماری ها و علائمی را که در برابر آن استفاده می شود ، ببینید.
* کلیه اطلاعات براساس تحقیقات علمی منتشر شده است

Google Play badgeApp Store badge