Medicine 2019-Aug

Successful blind lung isolation with the use of a novel double-lumen endobronchial tube in a patient undergoing lung transplantation with massive pulmonary secretion: A case report.

فقط کاربران ثبت نام شده می توانند مقالات را ترجمه کنند
ورود به سیستم / ثبت نام
پیوند در کلیپ بورد ذخیره می شود
Yijun Seo
Namo Kim
Hyo Paik
Dahee Park
Young Oh

کلید واژه ها

خلاصه

Precise lung isolation technique with visual confirmation is essential for thoracic surgeries to create a safe and clear surgical field. However, in certain situations, such as when patients have massive pulmonary secretion or when the fiberoptic bronchoscopy (FOB) is not applicable, lung isolation has been performed blindly.A 52-year-old woman, whose airway was unable to visualize with FOB due to massive pulmonary secretion, was presented for bilateral sequential lung transplantation. Extracorporeal membranous oxygenation, tracheostomy, and mechanical ventilation were applied to the patient for 39 days preoperatively as a bridge for lung transplantation.Patient was diagnosed with an idiopathic pulmonary fibrosis and obesity.Initially, height-based blind positioning with a conventional double-lumen endobronchial tube (DLT) failed to ventilate the patient properly, and the confirmation of DLT positioning with FOB was impossible due to massive pulmonary secretion. Therefore, a novel DLT (ANKOR DLT) that has one more cuff, located at a point between the distal opening of the tracheal lumen and the starting point of bronchial cuff, than conventional DLT was used for the lung isolation in the patient.After the completion of lung graft, FOB finding showed that the ANKOR DLT was optimally positioned at the tracheobronchial tree of the patient, and its depth was 2.5 cm shallower than that of the conventional tube.ANKOR DLT would be a feasible choice to achieve successful blind lung isolation when the use of FOB is impossible to achieve the optimal lung isolation.

به صفحه فیس بوک ما بپیوندید

کاملترین پایگاه داده گیاهان دارویی با پشتیبانی علمی

  • به 55 زبان کار می کند
  • درمان های گیاهی با پشتوانه علم
  • شناسایی گیاهان توسط تصویر
  • نقشه GPS تعاملی - گیاهان را در مکان نشان دهید (به زودی)
  • انتشارات علمی مربوط به جستجوی خود را بخوانید
  • گیاهان دارویی را با توجه به اثرات آنها جستجو کنید
  • علایق خود را سازماندهی کنید و با تحقیقات اخبار ، آزمایشات بالینی و حق ثبت اختراع در جریان باشید

علامت یا بیماری را تایپ کنید و در مورد گیاهانی که ممکن است به شما کمک کنند ، بخوانید ، یک گیاه تایپ کنید و بیماری ها و علائمی را که در برابر آن استفاده می شود ، ببینید.
* کلیه اطلاعات براساس تحقیقات علمی منتشر شده است

Google Play badgeApp Store badge