Persian
Albanian
Arabic
Armenian
Azerbaijani
Belarusian
Bengali
Bosnian
Catalan
Czech
Danish
Deutsch
Dutch
English
Estonian
Finnish
Français
Greek
Haitian Creole
Hebrew
Hindi
Hungarian
Icelandic
Indonesian
Irish
Italian
Japanese
Korean
Latvian
Lithuanian
Macedonian
Mongolian
Norwegian
Persian
Polish
Portuguese
Romanian
Russian
Serbian
Slovak
Slovenian
Spanish
Swahili
Swedish
Turkish
Ukrainian
Vietnamese
Български
中文(简体)
中文(繁體)
EuroIntervention 2014-Mar

Transfemoral aortic valve replacement with the repositionable Lotus Valve System in high surgical risk patients: the REPRISE I study.

فقط کاربران ثبت نام شده می توانند مقالات را ترجمه کنند
ورود به سیستم / ثبت نام
پیوند در کلیپ بورد ذخیره می شود
Ian T Meredith
Stephen G Worthley
Robert J Whitbourn
Paul Antonis
Joseph K Montarello
Andrew E Newcomb
Siohban Lockwood
Nicole Haratani
Dominic J Allocco
Keith D Dawkins

کلید واژه ها

خلاصه

OBJECTIVE

To assess outcomes with a new fully repositionable and retrievable valve for transcatheter aortic valve replacement (TAVR).

RESULTS

The Lotus Aortic Valve System is designed to facilitate precise positioning and minimise paravalvular regurgitation. REPRISE I enrolled symptomatic, high-surgical-risk patients with severe aortic stenosis. The primary endpoint (clinical procedural success) included successful implantation without major adverse cardiovascular or cerebrovascular events (MACCE). In all patients (N=11) the first Lotus Valve was successfully deployed. Partial resheathing to facilitate accurate placement was attempted and successfully performed in four patients; none required full retrieval. The primary endpoint was achieved in 9/11 with no in-hospital MACCE in 10/11. There was one major stroke; in another patient, discharge mean aortic gradient was 22 mmHg (above the primary endpoint threshold of 20 mmHg), but improved to 15 mmHg at 30 days. The cohort's mean aortic gradient decreased from 53.9±20.9 mmHg at baseline to 15.4±4.6 mmHg (p<0.001) at one year; valve area increased from 0.7±0.2 cm2 to 1.5±0.2 cm2 (p<0.001). Discharge paravalvular aortic regurgitation, adjudicated by an independent core laboratory, was mild (n=2), trivial (n=1), or absent (n=8). Four patients required a permanent pacemaker post-procedure. There were no deaths, myocardial infarctions or new strokes through one year.

CONCLUSIONS

Initial results support proof-of-concept with the Lotus Valve for TAVR.

به صفحه فیس بوک ما بپیوندید

کاملترین پایگاه داده گیاهان دارویی با پشتیبانی علمی

  • به 55 زبان کار می کند
  • درمان های گیاهی با پشتوانه علم
  • شناسایی گیاهان توسط تصویر
  • نقشه GPS تعاملی - گیاهان را در مکان نشان دهید (به زودی)
  • انتشارات علمی مربوط به جستجوی خود را بخوانید
  • گیاهان دارویی را با توجه به اثرات آنها جستجو کنید
  • علایق خود را سازماندهی کنید و با تحقیقات اخبار ، آزمایشات بالینی و حق ثبت اختراع در جریان باشید

علامت یا بیماری را تایپ کنید و در مورد گیاهانی که ممکن است به شما کمک کنند ، بخوانید ، یک گیاه تایپ کنید و بیماری ها و علائمی را که در برابر آن استفاده می شود ، ببینید.
* کلیه اطلاعات براساس تحقیقات علمی منتشر شده است

Google Play badgeApp Store badge