Persian
Albanian
Arabic
Armenian
Azerbaijani
Belarusian
Bengali
Bosnian
Catalan
Czech
Danish
Deutsch
Dutch
English
Estonian
Finnish
Français
Greek
Haitian Creole
Hebrew
Hindi
Hungarian
Icelandic
Indonesian
Irish
Italian
Japanese
Korean
Latvian
Lithuanian
Macedonian
Mongolian
Norwegian
Persian
Polish
Portuguese
Romanian
Russian
Serbian
Slovak
Slovenian
Spanish
Swahili
Swedish
Turkish
Ukrainian
Vietnamese
Български
中文(简体)
中文(繁體)
Computer Methods in Biomechanics and Biomedical Engineering 2020-Aug

Influence of lubricating conditions on the two-body wear behavior and hardness of titanium alloys for biomedical applications

فقط کاربران ثبت نام شده می توانند مقالات را ترجمه کنند
ورود به سیستم / ثبت نام
پیوند در کلیپ بورد ذخیره می شود
Efe Yilmaz

کلید واژه ها

خلاصه

Commercially pure titanium and titanium alloys are often preferred in biomedical applications due to their high biocompatibility behavior. However, the inadequate wear, fatigue and corrosion resistance of titanium alloys limit their use as a biomaterial in the human body. Furthermore, these alloys may contain such as aluminum and vanadium elements that can damage the nervous system. The aim of this in vitro study was to evaluate the influence of lubrication conditions on the two-body wear behavior of pure titanium, Ti-2.5Si-5Zr, Ti-5Si-5Zr, and Ti-6Al-4V using dual-axis computer-controlled wear simulator device. The mean wear volume loss of all test specimens after the two-body wear test procedures were determined to use a non-contact 3D profilometer. The alloys hardness and microstructures were evaluated using the Vickers indention method, scanning electron microscopy (SEM), X-ray spectroscopy (EDS), and X-ray diffraction (XRD) analysis. The hardness of Ti-6Al-4V titanium alloy material was significantly greater than the other alloy materials and cp-Ti. The mean wear volume loss of Ti-5Si-5Zr test specimens was lower than the other test group specimens irrespective of lubrication conditions. It was concluded, the two-body wear resistance of the alloy formed with the addition of silica to the pure titanium is increased after both wear test procedures. However, for the test materials in this study considered, correlations between the two-body wear resistance and hardness were found to be insignificant.

Keywords: Biomedical application; titanium alloys; two-body wear; volume loss.

به صفحه فیس بوک ما بپیوندید

کاملترین پایگاه داده گیاهان دارویی با پشتیبانی علمی

  • به 55 زبان کار می کند
  • درمان های گیاهی با پشتوانه علم
  • شناسایی گیاهان توسط تصویر
  • نقشه GPS تعاملی - گیاهان را در مکان نشان دهید (به زودی)
  • انتشارات علمی مربوط به جستجوی خود را بخوانید
  • گیاهان دارویی را با توجه به اثرات آنها جستجو کنید
  • علایق خود را سازماندهی کنید و با تحقیقات اخبار ، آزمایشات بالینی و حق ثبت اختراع در جریان باشید

علامت یا بیماری را تایپ کنید و در مورد گیاهانی که ممکن است به شما کمک کنند ، بخوانید ، یک گیاه تایپ کنید و بیماری ها و علائمی را که در برابر آن استفاده می شود ، ببینید.
* کلیه اطلاعات براساس تحقیقات علمی منتشر شده است

Google Play badgeApp Store badge