Journal of Shoulder and Elbow Surgery 2019-Apr

A biomechanical study of headless compression screws versus a locking plate in radial head fracture fixation.

Vain rekisteröityneet käyttäjät voivat kääntää artikkeleita
Kirjaudu sisään Rekisteröidy
Linkki tallennetaan leikepöydälle
Paul Rebgetz
Luca Daniele
Ian Underhill
Andreas Öchsner
Fraser Taylor

Avainsanat

Abstrakti

Fixation of a 3-part radial head fracture with cannulated compression screws will show equivalent stiffness to a locking plate under axial load. Debate exists regarding the management of Mason type III fractures, with many believing that open reduction and internal fixation provides advantages over other options. By virtue of their subarticular placement, screw fixation is less likely to cause impingement compared with plate fixation, which can result in loss of rotation and requirement for hardware removal. Insufficient fixation stability can lead to nonunions, necrosis of the radial head, pain, and instability. We tested the mechanical stability of fixation of simulated radial head fractures using headless compression screws compared with standard plate construct.Standardized test constructs were created with repeatable osteotomy cuts and hardware placement on each Synbone model (Synbone AG, Malans, Switzerland). We presectioned 22 proximal radius Synbone models to simulate a 3-part radial head fracture. The models were fixed using a radial head locking plate or headless compression screws in a tripod construct. The constructs were potted into a compression test jig using 2-part epoxy resin. Compression testing was performed using a 30-kN Instron Universal machine (Instron, Norwood, MA, USA). The compression tool was spherical, representing the surface of the capitellum.There was no significant difference between the stiffness of the Synbone constructs under axial load.There was no significant difference between fixation stiffness of a 3-part radial head fracture with headless compression screws in a tripod structure vs. a locking plate in Synbone. Further study is required to allow clinical application.

Liity facebook-sivullemme

Täydellisin lääketieteellinen tietokanta tieteen tukemana

  • Toimii 55 kielellä
  • Yrttilääkkeet tieteen tukemana
  • Yrttien tunnistaminen kuvan perusteella
  • Interaktiivinen GPS-kartta - merkitse yrtit sijaintiin (tulossa pian)
  • Lue hakuusi liittyviä tieteellisiä julkaisuja
  • Hae lääkekasveja niiden vaikutusten perusteella
  • Järjestä kiinnostuksesi ja pysy ajan tasalla uutisista, kliinisistä tutkimuksista ja patenteista

Kirjoita oire tai sairaus ja lue yrtteistä, jotka saattavat auttaa, kirjoita yrtti ja näe taudit ja oireet, joita vastaan sitä käytetään.
* Kaikki tiedot perustuvat julkaistuun tieteelliseen tutkimukseen

Google Play badgeApp Store badge