Finnish
Albanian
Arabic
Armenian
Azerbaijani
Belarusian
Bengali
Bosnian
Catalan
Czech
Danish
Deutsch
Dutch
English
Estonian
Finnish
Français
Greek
Haitian Creole
Hebrew
Hindi
Hungarian
Icelandic
Indonesian
Irish
Italian
Japanese
Korean
Latvian
Lithuanian
Macedonian
Mongolian
Norwegian
Persian
Polish
Portuguese
Romanian
Russian
Serbian
Slovak
Slovenian
Spanish
Swahili
Swedish
Turkish
Ukrainian
Vietnamese
Български
中文(简体)
中文(繁體)
Kaku igaku. The Japanese journal of nuclear medicine 1992-Jan

[Arterial clearance and cerebral uptake of Tc-99m ECD in patients with cerebrovascular disease compared with PET].

Vain rekisteröityneet käyttäjät voivat kääntää artikkeleita
Kirjaudu sisään Rekisteröidy
Linkki tallennetaan leikepöydälle
F Shishido
K Uemura
M Murakami
A Inugami
T Ogawa
S Higano
H Fujita
E Shimosegawa
I Kanno
Y Aizawa

Avainsanat

Abstrakti

Technetium-99m ethyl cysteinate dimer (ECD) has recently developed for SPECT imaging in assessment of cerebral perfusion. We evaluated the arterial blood clearance and the regional brain uptake of Tc-99m ECD compared with the regional CBF measured by PET in patients with cerebrovascular disease. Nine patients with diagnosis of cerebral ischemic disorders (N = 7) and cerebral hemorrhage (N = 2) were studied. PET study was performed with HEADTOME IV by O-15 steady state inhalation method. Immediately after the PET study, 555-740 MBq (5-20 mCi) of Tc-99m ECD was injected intravenously. After injection arterial blood sampling was performed sequentially, and we separated lipophilic fraction from whole blood using ethyl acetate in two cases. The SPECT imaging with Tc-99m ECD (ECD-SPECT) was started 5 min (first imaging) and 60 min (second imaging) after the administration using a high resolution ring type SPECT system (HEADTOME II). Several ROIs were placed on practically the same anatomical location on both SPECT and PET images. Clearance of the tracer in arterial whole blood and lipophilic fraction was rapid. Concerning to the distribution pattern of ECD-SPECT images there was no differences between the 1st imaging and the 2nd imaging, although about 15% of diffuse decrease of Tc-99m ECD uptake was shown in the 2nd images. The brain distribution of ECD-SPECT was comparable to the pattern of CBF image by PET. The regional relative counts of ECD-SPECT corresponded closely to the CBF value by PET, but it was no linear correlation between brain uptake of ECD-SPECT and PET-CBF.(ABSTRACT TRUNCATED AT 250 WORDS)

Liity facebook-sivullemme

Täydellisin lääketieteellinen tietokanta tieteen tukemana

  • Toimii 55 kielellä
  • Yrttilääkkeet tieteen tukemana
  • Yrttien tunnistaminen kuvan perusteella
  • Interaktiivinen GPS-kartta - merkitse yrtit sijaintiin (tulossa pian)
  • Lue hakuusi liittyviä tieteellisiä julkaisuja
  • Hae lääkekasveja niiden vaikutusten perusteella
  • Järjestä kiinnostuksesi ja pysy ajan tasalla uutisista, kliinisistä tutkimuksista ja patenteista

Kirjoita oire tai sairaus ja lue yrtteistä, jotka saattavat auttaa, kirjoita yrtti ja näe taudit ja oireet, joita vastaan sitä käytetään.
* Kaikki tiedot perustuvat julkaistuun tieteelliseen tutkimukseen

Google Play badgeApp Store badge