Journal of chromatography. B, Biomedical sciences and applications 1999-Oct

Capillary zone electrophoresis of potassium in human vitreous humour: validation of a new method.

Vain rekisteröityneet käyttäjät voivat kääntää artikkeleita
Kirjaudu sisään Rekisteröidy
Linkki tallennetaan leikepöydälle
F Tagliaro
G Manetto
F Cittadini
D Marchetti
F Bortolotti
M Marigo

Avainsanat

Abstrakti

The analysis of potassium in the vitreous humour has long been regarded as an important tool in medicolegal and forensic toxicological investigation, particularly for the determination of the post-mortem interval. The present work was aimed at the optimisation and validation of a reliable, simple and fast capillary electrophoresis method for potassium analysis in the human vitreous humour with indirect UV detection at a wavelength of 214 nm. Electrophoretic separations were carried out in a running buffer comprising 5 mM imidazole, 5 mM 18-crown-6 ether and 6 mM D,L alpha-hydroxybutyric acid (HIBA), adjusted to pH 4.5. Constant voltage runs were carried out by applying a voltage of 500 V/cm at 25 degrees C. The samples were injected in the hydrodynamic mode at the anodic end of the capillary (0.5 p.s.i. for 10 s; 1 p.s.i. = 6894.76 Pa). The method showed good linearity in the concentration range from 6.5 mM to 16.25 microM, with an r2 value of 0.9994. The limit of detection, based on a signal-to-noise ratio of three, was 9.0 microM. Absolute intra-day RSDs of migration times were <0.40%, while the day-to-day values were < or =1.72%. Absolute peak area reproducibility was always better than 2.50%. A comparison of capillary electrophoresis with flame photometry on twelve real autopsy samples showed an excellent correlation with an r2 value of 0.9333. A preliminary application to real cases (20 subjects) was carried out plotting vitreous humour potassium vs. post-mortem interval with a resulting r2 of 0.904 and a Y-intercept of 4.75 mM, in agreement with the existing literature.

Liity facebook-sivullemme

Täydellisin lääketieteellinen tietokanta tieteen tukemana

  • Toimii 55 kielellä
  • Yrttilääkkeet tieteen tukemana
  • Yrttien tunnistaminen kuvan perusteella
  • Interaktiivinen GPS-kartta - merkitse yrtit sijaintiin (tulossa pian)
  • Lue hakuusi liittyviä tieteellisiä julkaisuja
  • Hae lääkekasveja niiden vaikutusten perusteella
  • Järjestä kiinnostuksesi ja pysy ajan tasalla uutisista, kliinisistä tutkimuksista ja patenteista

Kirjoita oire tai sairaus ja lue yrtteistä, jotka saattavat auttaa, kirjoita yrtti ja näe taudit ja oireet, joita vastaan sitä käytetään.
* Kaikki tiedot perustuvat julkaistuun tieteelliseen tutkimukseen

Google Play badgeApp Store badge