Finnish
Albanian
Arabic
Armenian
Azerbaijani
Belarusian
Bengali
Bosnian
Catalan
Czech
Danish
Deutsch
Dutch
English
Estonian
Finnish
Français
Greek
Haitian Creole
Hebrew
Hindi
Hungarian
Icelandic
Indonesian
Irish
Italian
Japanese
Korean
Latvian
Lithuanian
Macedonian
Mongolian
Norwegian
Persian
Polish
Portuguese
Romanian
Russian
Serbian
Slovak
Slovenian
Spanish
Swahili
Swedish
Turkish
Ukrainian
Vietnamese
Български
中文(简体)
中文(繁體)
Cytometry 1990

Chlorophyll a fluorescence measurements of isolated spinach thylakoids obtained by using single-laser-based flow cytometry.

Vain rekisteröityneet käyttäjät voivat kääntää artikkeleita
Kirjaudu sisään Rekisteröidy
Linkki tallennetaan leikepöydälle
C Xu
J Auger
Govindjee

Avainsanat

Abstrakti

Flow cytometry data of spinach thylakoid membrane preparations indicate the presence of a homogeneous thylakoid population. Fluorescence data from a flow cytometer and comparison with data from two other fluorometers show that chlorophyll a fluorescence detected with a flow cytometer has the character of maximum fluorescence (Fmax), not of the constant component (Fo). This conclusion is important since Fo measures fluorescence that is affected mostly by changes in excitation energy transfer and Fmax-Fo (the variable fluorescence) by changes in photochemistry. This was demonstrated by: 1) The light intensity as well as diffusion rate dependence of the quenching effect of various quinones (p-benzoquinone, phenyl-benzoquinone, and 2,5-dibromo-3-methyl-6-isopropyl-p-benzoquinone, DBMIB) on fluorescence yield; quenching for the same concentration of these quinones was lower at the higher than at the lower light intensities. 2) Temperature dependence of the fluorescence yield; increasing the temperature from 20 to 70 degrees C did not show an increase in fluorescence yield using a flow cytometer in contrast to measurements with weak excitation light, but similar to those obtained for Fmax. 3) Addition of an inhibitor diuron up to 100 microM did not change the fluorescence intensity. A comparison of quenching of fluorescence by various quinones obtained by flow cytometry with those by other fluorometers suggests that the high intensity used in the cytometry produces unique results: the rate of reduction of quinones in much larger than the rate of equilibration with the bulk quinones.

Liity facebook-sivullemme

Täydellisin lääketieteellinen tietokanta tieteen tukemana

  • Toimii 55 kielellä
  • Yrttilääkkeet tieteen tukemana
  • Yrttien tunnistaminen kuvan perusteella
  • Interaktiivinen GPS-kartta - merkitse yrtit sijaintiin (tulossa pian)
  • Lue hakuusi liittyviä tieteellisiä julkaisuja
  • Hae lääkekasveja niiden vaikutusten perusteella
  • Järjestä kiinnostuksesi ja pysy ajan tasalla uutisista, kliinisistä tutkimuksista ja patenteista

Kirjoita oire tai sairaus ja lue yrtteistä, jotka saattavat auttaa, kirjoita yrtti ja näe taudit ja oireet, joita vastaan sitä käytetään.
* Kaikki tiedot perustuvat julkaistuun tieteelliseen tutkimukseen

Google Play badgeApp Store badge