Journal of Analytical Toxicology 2015-May

Evidence of Sulfur Mustard Exposure in Human Plasma by LC-ESI-MS-MS Detection of the Albumin-Derived Alkylated HETE-CP Dipeptide and Chromatographic Investigation of Its Cis/Trans Isomerism.

Vain rekisteröityneet käyttäjät voivat kääntää artikkeleita
Kirjaudu sisään Rekisteröidy
Linkki tallennetaan leikepöydälle
Felix Gandor
Michael Gawlik
Horst Thiermann
Harald John

Avainsanat

Abstrakti

Sulfur mustard (SM) is a chemical warfare agent that causes painful blisters and chemically modifies endogenous biomacromolecules by alkylation to hydroxyethylthioethyl (HETE) adducts representing valuable long-term markers for post-exposure analysis. The albumin adduct formed in human plasma in vitro (HETE bound to the side chain of cysteine 34) was isolated and cleaved by current lots of pronase primarily generating the internal modified dipeptide (HETE-cysteine-proline, HETE-CP) instead of the formerly reported HETE-CPF tripeptide. The analyte was detected by liquid chromatography-electrospray ionization tandem-mass spectrometry (LC-ESI-MS-MS). In principle, HETE-CP undergoes a dynamic on-column equilibrium of cis-trans isomerism thus requiring separation at 50°C to obtain one narrow peak. Accordingly, we developed both a novel longer lasting but more sensitive microbore (1 mm i.d., flow 30 µL/min, cycle time 60 min, LOD 50 nM) and a faster, less sensitive narrowbore (2.1 mm i.d., 200 µL/min, cycle time 16 min, LOD 100 nM, both on Atlantis T3 material at 50°C) LC-ESI-MS-MS method suitable for verification analysis. The corresponding tri- and tetrapeptide, Q(HETE)-CPF were monitored simultaneously. HETE-CP peak areas were directly proportional to SM concentrations added to plasma in vitro (0.05-100 µM). Albumin adducts formed by deuterated SM (d8-SM) served as internal standard.

Liity facebook-sivullemme

Täydellisin lääketieteellinen tietokanta tieteen tukemana

  • Toimii 55 kielellä
  • Yrttilääkkeet tieteen tukemana
  • Yrttien tunnistaminen kuvan perusteella
  • Interaktiivinen GPS-kartta - merkitse yrtit sijaintiin (tulossa pian)
  • Lue hakuusi liittyviä tieteellisiä julkaisuja
  • Hae lääkekasveja niiden vaikutusten perusteella
  • Järjestä kiinnostuksesi ja pysy ajan tasalla uutisista, kliinisistä tutkimuksista ja patenteista

Kirjoita oire tai sairaus ja lue yrtteistä, jotka saattavat auttaa, kirjoita yrtti ja näe taudit ja oireet, joita vastaan sitä käytetään.
* Kaikki tiedot perustuvat julkaistuun tieteelliseen tutkimukseen

Google Play badgeApp Store badge