Finnish
Albanian
Arabic
Armenian
Azerbaijani
Belarusian
Bengali
Bosnian
Catalan
Czech
Danish
Deutsch
Dutch
English
Estonian
Finnish
Français
Greek
Haitian Creole
Hebrew
Hindi
Hungarian
Icelandic
Indonesian
Irish
Italian
Japanese
Korean
Latvian
Lithuanian
Macedonian
Mongolian
Norwegian
Persian
Polish
Portuguese
Romanian
Russian
Serbian
Slovak
Slovenian
Spanish
Swahili
Swedish
Turkish
Ukrainian
Vietnamese
Български
中文(简体)
中文(繁體)
Annals of Thoracic Surgery 2000-Aug

Mediastinal false aneurysm after thoracic aortic surgery.

Vain rekisteröityneet käyttäjät voivat kääntää artikkeleita
Kirjaudu sisään Rekisteröidy
Linkki tallennetaan leikepöydälle
T Katsumata
N Moorjani
G Vaccari
S Westaby

Avainsanat

Abstrakti

BACKGROUND

Postoperative mediastinal false aneurysm is associated with a substantial morbidity and mortality. Surgical treatment is mandatory, although the individual approach varies according to the type of pathologic process, infection status, and site of origin of the aneurysm.

METHODS

Between April 1993 and February 1999, we treated 10 patients, aged 25 to 73 years, with anastomotic mediastinal false aneurysm originating from the proximal thoracic aorta. Nine had undergone prior operations on the ascending aorta (7, type A dissection repair; 1, aortitis; 1, root abscess) with a Dacron conduit (n = 5) or valved conduit (n = 4). The last patient had undergone valve replacement for excavating aortic root sepsis. False aneurysms were detected from 2 to 70 months after the most recent operation. Three patients had positive tissue cultures. The surgical procedure was direct suture repair of the disrupted anastomosis in 5, root or ascending aortic replacement with an aortic homograft in 4, and Dacron graft interposition in 1. Hypothermic low-flow perfusion with or without circulatory arrest was used in all patients.

RESULTS

There was one hospital death caused by staphylococcal mediastinitis. A false aneurysm recurred after direct suture repair in 2 patients with underlying type A dissection or aortitis. This resulted in one late death. One patient experienced a neurologic event during removal of an infected vascular graft. All 8 surviving patients are alive and well after a mean follow-up of 2 years. Three patients with mycotic false aneurysms remain free from infection after aortic homograft replacement.

CONCLUSIONS

Mediastinal false aneurysms are surgically taxing. Low-flow hypothermic perfusion with or without circulatory arrest allows safe reentry. Radical surgery provides a satisfactory outcome in infected patients. Local repair of suture dehiscence in pathologic tissues may predispose to recurrence. We suspect that excessive use of formalin in gelatin-resorcin-formol glue may predispose to tissue necrosis.

Liity facebook-sivullemme

Täydellisin lääketieteellinen tietokanta tieteen tukemana

  • Toimii 55 kielellä
  • Yrttilääkkeet tieteen tukemana
  • Yrttien tunnistaminen kuvan perusteella
  • Interaktiivinen GPS-kartta - merkitse yrtit sijaintiin (tulossa pian)
  • Lue hakuusi liittyviä tieteellisiä julkaisuja
  • Hae lääkekasveja niiden vaikutusten perusteella
  • Järjestä kiinnostuksesi ja pysy ajan tasalla uutisista, kliinisistä tutkimuksista ja patenteista

Kirjoita oire tai sairaus ja lue yrtteistä, jotka saattavat auttaa, kirjoita yrtti ja näe taudit ja oireet, joita vastaan sitä käytetään.
* Kaikki tiedot perustuvat julkaistuun tieteelliseen tutkimukseen

Google Play badgeApp Store badge