Laryngoscope 2014-May

Spontaneous cerebrospinal fluid effusion of the temporal bone: repair, audiological outcomes, and obesity.

Vain rekisteröityneet käyttäjät voivat kääntää artikkeleita
Kirjaudu sisään Rekisteröidy
Linkki tallennetaan leikepöydälle
Hwa J Son
Alexandre Karkas
Patrick Buchanan
Jonathan P Giurintano
Philip Theodosopoulos
Myles L Pensak
Ravi N Samy

Avainsanat

Abstrakti

OBJECTIVE

Spontaneous occurrence of otogenic cerebrospinal fluid (CSF) effusion is now far more prevalent than causes related to infections, prior surgeries, or trauma-trends that may be increasing because of higher rates of obesity and improved diagnostic awareness. In our patient cohort with spontaneous CSF effusion, we report its association with obesity and audiological findings before and after surgery.

METHODS

Retrospective study.

METHODS

In our 45 patients (46 ears) with CSF effusion (with or without lateral skull base meningoencephaloceles), we report clinical data, imaging studies, audiogram results, operative techniques, and recurrence rates. Causes included 33 spontaneous, 10 due to chronic otitis media, one iatrogenic, and one traumatic.

RESULTS

Body mass index (BMI) averaged 35 overall (37 for spontaneous type and 32 for nonspontaneous type). Surgical repair of skull base defect was performed using three middle fossa approaches, 24 combined transmastoid/middle fossa, and 19 transmastoid alone. Overall recurrence of CSF leaks was 6.5%. Thirty patients had audiograms available. Sensorineural hearing loss occurred in 10% of patients. Air-bone gap improved by ≥ 15 dB in 20% of patients and worsened by ≥ 15 dB in 6.7% of patients.

CONCLUSIONS

Patients with spontaneous CSF effusion had a BMI higher than in the nonspontaneous group, but the difference was not statistically significant. However, the dramatic trend toward spontaneous CSF effusion heightens the need for clinician's acumen for diagnosis, particularly in overweight/obese patients. Our audiological outcomes confirm the efficacy of surgical approaches in correcting conductive hearing loss and preserving bone conduction, although hearing loss is a risk during surgical repair.

METHODS

4. Laryngoscope, 124:1204-1208, 2014.

Liity facebook-sivullemme

Täydellisin lääketieteellinen tietokanta tieteen tukemana

  • Toimii 55 kielellä
  • Yrttilääkkeet tieteen tukemana
  • Yrttien tunnistaminen kuvan perusteella
  • Interaktiivinen GPS-kartta - merkitse yrtit sijaintiin (tulossa pian)
  • Lue hakuusi liittyviä tieteellisiä julkaisuja
  • Hae lääkekasveja niiden vaikutusten perusteella
  • Järjestä kiinnostuksesi ja pysy ajan tasalla uutisista, kliinisistä tutkimuksista ja patenteista

Kirjoita oire tai sairaus ja lue yrtteistä, jotka saattavat auttaa, kirjoita yrtti ja näe taudit ja oireet, joita vastaan sitä käytetään.
* Kaikki tiedot perustuvat julkaistuun tieteelliseen tutkimukseen

Google Play badgeApp Store badge