Journal of Cardiovascular Medicine 2018-Nov

Transfemoral aortic valve implantation with new-generation devices: the repositionable Lotus vs. the balloon-expandable Edwards Sapien 3 valve.

Vain rekisteröityneet käyttäjät voivat kääntää artikkeleita
Kirjaudu sisään Rekisteröidy
Linkki tallennetaan leikepöydälle
Luca Nai Fovino
Mostafa R A Badawy
Chiara Fraccaro
Augusto D'Onofrio
Paola A M Purita
Anna C Frigo
Paola Tellaroli
Agnifili Mauro
Maurizio Tusa
Massimo Napodano

Avainsanat

Abstrakti

BACKGROUND

New-generation transcatheter heart valves have been developed to reduce complications of transcatheter aortic valve implantation (TAVI). With this study we sought to compare procedural and 30-day outcomes of the new-generation repositionable Boston Scientific Lotus (Lotus) and the balloon-expandable Edwards Sapien 3 (ES3) transcatheter heart valves.

METHODS

A total of 315 patients with severe symptomatic aortic stenosis undergoing transfemoral TAVI with Lotus or ES3 included in two large Italian registries were considered for this analysis. After propensity matching, 93 matched pairs of patients were included. Outcomes were evaluated according to Valve Academic Research Consortium-2 definition at discharge and 30 days.

RESULTS

There were no differences in baseline characteristics, except for lower mean aortic gradient and larger mean aortic annulus in the ES3-treated patients. Valve Academic Research Consortium-2 defined device success was high and comparable between groups (97.8 for Lotus vs. 98.9% for ES3, P = 0.09). The frequency of moderate/severe paravalvular leak was low and similar for both devices (2.2 vs. 1.1%, P = 0.10). At 30 days, both groups showed low all-cause mortality (5.4 vs. 1.1%, P = 0.10) and rates of disabling stroke (3.2 vs. 1.1%, P = 0.31). New pacemaker implantation was more common after Lotus deployment (31.7 vs. 10.5%, P < 0.001).

CONCLUSIONS

Transfemoral TAVI with both Lotus and ES3 resulted in favorable clinical and hemodynamic procedural and 30-day outcomes. Rates of significant paravalvular leak were low with both devices. The Lotus valve was associated with higher risk of pacemaker implantation.

Liity facebook-sivullemme

Täydellisin lääketieteellinen tietokanta tieteen tukemana

  • Toimii 55 kielellä
  • Yrttilääkkeet tieteen tukemana
  • Yrttien tunnistaminen kuvan perusteella
  • Interaktiivinen GPS-kartta - merkitse yrtit sijaintiin (tulossa pian)
  • Lue hakuusi liittyviä tieteellisiä julkaisuja
  • Hae lääkekasveja niiden vaikutusten perusteella
  • Järjestä kiinnostuksesi ja pysy ajan tasalla uutisista, kliinisistä tutkimuksista ja patenteista

Kirjoita oire tai sairaus ja lue yrtteistä, jotka saattavat auttaa, kirjoita yrtti ja näe taudit ja oireet, joita vastaan sitä käytetään.
* Kaikki tiedot perustuvat julkaistuun tieteelliseen tutkimukseen

Google Play badgeApp Store badge