Finnish
Albanian
Arabic
Armenian
Azerbaijani
Belarusian
Bengali
Bosnian
Catalan
Czech
Danish
Deutsch
Dutch
English
Estonian
Finnish
Français
Greek
Haitian Creole
Hebrew
Hindi
Hungarian
Icelandic
Indonesian
Irish
Italian
Japanese
Korean
Latvian
Lithuanian
Macedonian
Mongolian
Norwegian
Persian
Polish
Portuguese
Romanian
Russian
Serbian
Slovak
Slovenian
Spanish
Swahili
Swedish
Turkish
Ukrainian
Vietnamese
Български
中文(简体)
中文(繁體)
PLoS ONE 2017

Using the Hephaistos orthotic device to study countermeasure effectiveness of neuromuscular electrical stimulation and dietary lupin protein supplementation, a randomised controlled trial.

Vain rekisteröityneet käyttäjät voivat kääntää artikkeleita
Kirjaudu sisään Rekisteröidy
Linkki tallennetaan leikepöydälle
Jochen Zange
Kathrin Schopen
Kirsten Albracht
Darius A Gerlach
Petra Frings-Meuthen
Nicola A Maffiuletti
Wilhelm Bloch
Jörn Rittweger

Avainsanat

Abstrakti

OBJECTIVE

The present study investigated whether neuromuscular electrical stimulation for 20 min twice a day with an electrode placed over the soleus muscle and nutritional supplementation with 19 g of protein rich lupin seeds can reduce the loss in volume and strength of the human calf musculature during long term unloading by wearing an orthotic unloading device.

METHODS

Thirteen healthy male subjects (age of 26.4 ± 3.7 years) wore a Hephaistos orthosis one leg for 60 days during all habitual activities. The leg side was randomly chosen for every subject. Six subjects only wore the orthosis as control group, and 7 subjects additionally received the countermeasure consisting of neuromuscular electrical stimulation of the soleus and lateral gastrocnemius muscles and lupin protein supplementation. Twenty-eight days before and on the penultimate day of the intervention cross-sectional images of the calf muscles were taken by magnetic resonance imaging (controls n = 5), and maximum voluntary torque (controls n = 6) of foot plantar flexion was estimated under isometric (extended knee, 90° knee flexion) and isokinetic conditions (extended knee), respectively.

RESULTS

After 58 days of wearing the orthosis the percentage loss of volume in the entire triceps surae muscle of the control subjects (-11.9 ± 4.4%, mean ± standard deviation) was reduced by the countermeasure (-3.5 ± 7.2%, p = 0.032). Wearing the orthosis generally reduced plantar flexion torques values, however, only when testing isometric contraction at 90° knee ankle the countermeasure effected a significantly lower percentage decrease of torque (-9.7 ± 7.2%, mean ± SD) in comparison with controls (-22.3 ± 11.2%, p = 0.032).

CONCLUSIONS

Unloading of calf musculature by an orthotic device resulted in the expected loss of muscle volume and maximum of plantar flexion torque. Neuromuscular electrical muscle stimulation and lupin protein supplementation could significantly reduce the process of atrophy.

BACKGROUND

ClinicalTrials.gov, identifier NCT02698878.

Liity facebook-sivullemme

Täydellisin lääketieteellinen tietokanta tieteen tukemana

  • Toimii 55 kielellä
  • Yrttilääkkeet tieteen tukemana
  • Yrttien tunnistaminen kuvan perusteella
  • Interaktiivinen GPS-kartta - merkitse yrtit sijaintiin (tulossa pian)
  • Lue hakuusi liittyviä tieteellisiä julkaisuja
  • Hae lääkekasveja niiden vaikutusten perusteella
  • Järjestä kiinnostuksesi ja pysy ajan tasalla uutisista, kliinisistä tutkimuksista ja patenteista

Kirjoita oire tai sairaus ja lue yrtteistä, jotka saattavat auttaa, kirjoita yrtti ja näe taudit ja oireet, joita vastaan sitä käytetään.
* Kaikki tiedot perustuvat julkaistuun tieteelliseen tutkimukseen

Google Play badgeApp Store badge