Français
Albanian
Arabic
Armenian
Azerbaijani
Belarusian
Bengali
Bosnian
Catalan
Czech
Danish
Deutsch
Dutch
English
Estonian
Finnish
Français
Greek
Haitian Creole
Hebrew
Hindi
Hungarian
Icelandic
Indonesian
Irish
Italian
Japanese
Korean
Latvian
Lithuanian
Macedonian
Mongolian
Norwegian
Persian
Polish
Portuguese
Romanian
Russian
Serbian
Slovak
Slovenian
Spanish
Swahili
Swedish
Turkish
Ukrainian
Vietnamese
Български
中文(简体)
中文(繁體)
Bioelectrochemistry 2010-Nov

Molecularly imprinted poly[bis(2,2'-bithienyl)methane] film with built-in molecular recognition sites for a piezoelectric microgravimetry chemosensor for selective determination of dopamine.

Seuls les utilisateurs enregistrés peuvent traduire des articles
Se connecter S'inscrire
Le lien est enregistré dans le presse-papiers
Agnieszka Pietrzyk
Subramanian Suriyanarayanan
Wlodzimierz Kutner
Eranda Maligaspe
Melvin E Zandler
Francis D'Souza

Mots clés

Abstrait

A piezoelectric microgravimetry (PM) chemosensor, featuring a film of molecularly imprinted polymer (MIP) of poly[bis(2,2'-bithienyl)methane] bearing either a 3,4-dihydroxyphenyl or benzo-18-crown-6 substituent, for selective determination of dopamine was devised and tested. A Pt/quartz resonator and a dopamine-templated MIP film, deposited by electropolymerization onto an underlayer of poly(bithiophene), served as the transducer and recognition element of the chemosensor, respectively. The UV-vis spectroscopic and XPS as well as electrochemical measurements verified completeness of the dopamine template extraction with a strong base solution. The extraction-generated molecular cavities featured recognition sites that served selective dopamine analyte binding. The SECM imaging substantiated the permeability characteristics of the template-free MIP film. The dopamine analyte was determined under FIA conditions with the PM detection. The lower limit of detection was 10nM dopamine at favorable conditions involving the 35 μL/min carrier solution flow rate and the injected sample volume of 1 mL. The sensitivity of the chemosensor increased almost fivefold when the poly(bithiophene) film coated Pt/quartz electrode was used instead of the bare Pt/quartz electrode as the substrate for deposition of the MIP film. The chemosensor successfully discriminated dopamine from structural and functional analogues, such as 2-phenylethylamine, histamine, and ascorbic acid. The optimum mean thickness of the MIP film was ∼220 nm.

Rejoignez notre
page facebook

La base de données d'herbes médicinales la plus complète soutenue par la science

  • Fonctionne en 55 langues
  • Cures à base de plantes soutenues par la science
  • Reconnaissance des herbes par image
  • Carte GPS interactive - étiquetez les herbes sur place (à venir)
  • Lisez les publications scientifiques liées à votre recherche
  • Rechercher les herbes médicinales par leurs effets
  • Organisez vos intérêts et restez à jour avec les nouvelles recherches, essais cliniques et brevets

Tapez un symptôme ou une maladie et lisez des informations sur les herbes qui pourraient aider, tapez une herbe et voyez les maladies et symptômes contre lesquels elle est utilisée.
* Toutes les informations sont basées sur des recherches scientifiques publiées

Google Play badgeApp Store badge