European journal of echocardiography : the journal of the Working Group on Echocardiography of the European Society of Cardiology 2008-Jan

Profound hypoxaemia corrected by PFO closure device in carcinoid heart disease.

Seuls les utilisateurs enregistrés peuvent traduire des articles
Se connecter S'inscrire
Le lien est enregistré dans le presse-papiers
Philip M Mottram
David J McGaw
Ian T Meredith
Roger E Peverill
Richard W Harper

Mots clés

Abstrait

A 66-year-old man with known metastatic carcinoid tumor presented with increasing dyspnoea, right heart failure and marked hypoxaemia which did not correct with oxygen. Echocardiography demonstrated severe tricuspid regurgitation, moderate pulmonary regurgitation and marked right heart dilatation. The inter-atrial septum was aneurysmal, with a large patent foramen ovale (PFO) with continuous right to left shunting. Cardiac catheterization demonstrated oxygen saturations of 96% in the pulmonary veins and 74% in the left atrium with a significant right to left shunt. During percutaneous closure of the PFO, anaesthetic induction resulted in marked systemic hypotension and worsening hypoxia related to systemic vasodilatation and increased shunting. PFO flow was temporarily obstructed with a sizing balloon resulting in a rapid increase in arterial oxygen saturation from 60% to >90%, but marked systemic hypotension due to acute left ventricular preload reduction, requiring volume replacement and adrenaline. Following deployment of a PFO occluder device, prominent pulsatile splaying of the right and left discs was noted due to the severe tricuspid regurgitation, resulting in some residual inter-atrial shunting. Arterial oxygen saturation was 83%, increasing to 92% at day 4 post-procedure as tissue organization occurred within the device, and the patient reported improvement in dyspnoea.

Rejoignez notre
page facebook

La base de données d'herbes médicinales la plus complète soutenue par la science

  • Fonctionne en 55 langues
  • Cures à base de plantes soutenues par la science
  • Reconnaissance des herbes par image
  • Carte GPS interactive - étiquetez les herbes sur place (à venir)
  • Lisez les publications scientifiques liées à votre recherche
  • Rechercher les herbes médicinales par leurs effets
  • Organisez vos intérêts et restez à jour avec les nouvelles recherches, essais cliniques et brevets

Tapez un symptôme ou une maladie et lisez des informations sur les herbes qui pourraient aider, tapez une herbe et voyez les maladies et symptômes contre lesquels elle est utilisée.
* Toutes les informations sont basées sur des recherches scientifiques publiées

Google Play badgeApp Store badge