Handchirurgie Mikrochirurgie Plastische Chirurgie 2015-Dec

Quantitative Assessment of Free Flap Viability with CEUS Using an Integrated Perfusion Software.

Seuls les utilisateurs enregistrés peuvent traduire des articles
Se connecter S'inscrire
Le lien est enregistré dans le presse-papiers
S Geis
S Klein
L Prantl
J Dolderer
P Lamby
E-M Jung

Mots clés

Abstrait

OBJECTIVE

New treatment strategies in oncology and trauma surgery lead to an increasing demand for soft tissue reconstruction with free tissue transfer. In previous studies, CEUS was proven to detect early flap failure. The aim of this study was to detect and quantify vascular disturbances after free flap transplantation using a fast integrated perfusion software tool.

METHODS

From 2011 to 2013, 33 patients were examined by one experienced radiologist using CEUS after a bolus injection of 1-2.4 ml of SonoVue(®). Flap perfusion was analysed qualitatively regarding contrast defects or delayed wash-in. Additionally, an integrated semi-quantitative analysis using time-intensity curve analysis (TIC) was performed. TIC analysis of the transplant was conducted on a centimetre-by-centimetre basis up to a penetration depth of 4 cm. The 2 perfusion parameters "Time to PEAK" and "Area under the Curve" were compared in patients without complications vs. patients with minor complications or complete flap loss to figure out significant differences. TtoPk is given in seconds (s) and Area is given in relative units (rU) Results: A regular postoperative process was observed in 26 (79%) patients. In contrast, 5 (15%) patients with partial superficial flap necrosis, 1 patient (3%) with complete flap loss and 1 patient (3%) with haematoma were observed. TtoPk revealed no significant differences, whereas Area revealed significantly lower perfusion values in the corresponding areas in patients with complications. The critical threshold for sufficient flap perfusion was set below 150 rU.

CONCLUSIONS

In conclusion, CEUS is a mobile and cost-effective opportunity to quantify tissue perfusion and can even be used almost without any restrictions in multi-morbid patients with renal and hepatic failure.

Rejoignez notre
page facebook

La base de données d'herbes médicinales la plus complète soutenue par la science

  • Fonctionne en 55 langues
  • Cures à base de plantes soutenues par la science
  • Reconnaissance des herbes par image
  • Carte GPS interactive - étiquetez les herbes sur place (à venir)
  • Lisez les publications scientifiques liées à votre recherche
  • Rechercher les herbes médicinales par leurs effets
  • Organisez vos intérêts et restez à jour avec les nouvelles recherches, essais cliniques et brevets

Tapez un symptôme ou une maladie et lisez des informations sur les herbes qui pourraient aider, tapez une herbe et voyez les maladies et symptômes contre lesquels elle est utilisée.
* Toutes les informations sont basées sur des recherches scientifiques publiées

Google Play badgeApp Store badge