Français
Albanian
Arabic
Armenian
Azerbaijani
Belarusian
Bengali
Bosnian
Catalan
Czech
Danish
Deutsch
Dutch
English
Estonian
Finnish
Français
Greek
Haitian Creole
Hebrew
Hindi
Hungarian
Icelandic
Indonesian
Irish
Italian
Japanese
Korean
Latvian
Lithuanian
Macedonian
Mongolian
Norwegian
Persian
Polish
Portuguese
Romanian
Russian
Serbian
Slovak
Slovenian
Spanish
Swahili
Swedish
Turkish
Ukrainian
Vietnamese
Български
中文(简体)
中文(繁體)
Clinical Chemistry 2000-May

Routine alpha-amylase assay using protected 4-nitrophenyl-1, 4-alpha-D-maltoheptaoside and a novel alpha-glucosidase.

Seuls les utilisateurs enregistrés peuvent traduire des articles
Se connecter S'inscrire
Le lien est enregistré dans le presse-papiers
K Lorentz

Mots clés

Abstrait

BACKGROUND

In contrast to numerous methods for measuring alpha-amylase activity, the approved IFCC reference method offers an invariable time-independent constant product pattern, thus avoiding possibly changing stoichiometric calculations. However, reference methods do not lend themselves to routine use, so that such methods need to be modified.

METHODS

Ethylidene-blocked 4-nitrophenylmaltoheptaoside (EPS-G7) is degraded to glucose and 4-nitrophenol in a coupled assay with a bacterial alpha-glucosidase under the following measurement conditions: 3.5 mmol/L EPS-G7, 7.1 kU/L alpha-glucosidase, 70 mmol/L sodium chloride, 1 mmol/L calcium chloride, 50 mmol/L HEPES, pH 7.15, at 37 degrees C. The increase of absorbance is continuously monitored for 3 min at 405 nm after a lag phase of 2 min.

RESULTS

Catalytic concentrations up to 15-fold higher than the upper reference limit can be determined without dilution. Precision studies in manual performance show CVs of 1.4-2. 6% (within-run) and 1.9-2.8% (day-to-day). There was no interference from 100 mmol/L glucose, 30 mmol/L triacylglycerols, 610 micromol/L bilirubin, and 2.95 g/L hemoglobin. The method closely correlates with other chromogenic assays. The preliminary 0.95 reference interval for adults, not dependent on age and sex, is 33.6-96.2 U/L.

CONCLUSIONS

The procedure is a robust adaptation of the reference method to routine use at 37 degrees C with increased sensitivity, fewer interferences, and reduced cost.

Rejoignez notre
page facebook

La base de données d'herbes médicinales la plus complète soutenue par la science

  • Fonctionne en 55 langues
  • Cures à base de plantes soutenues par la science
  • Reconnaissance des herbes par image
  • Carte GPS interactive - étiquetez les herbes sur place (à venir)
  • Lisez les publications scientifiques liées à votre recherche
  • Rechercher les herbes médicinales par leurs effets
  • Organisez vos intérêts et restez à jour avec les nouvelles recherches, essais cliniques et brevets

Tapez un symptôme ou une maladie et lisez des informations sur les herbes qui pourraient aider, tapez une herbe et voyez les maladies et symptômes contre lesquels elle est utilisée.
* Toutes les informations sont basées sur des recherches scientifiques publiées

Google Play badgeApp Store badge