Zhonghua yi xue za zhi 2006-Jul

[Values of intradermal skin test and serum sIgE detection in diagnosing Humulus scandens pollinosis].

Seuls les utilisateurs enregistrés peuvent traduire des articles
Se connecter S'inscrire
Le lien est enregistré dans le presse-papiers
Jia Yin
Rui-qi Wang
Hai-juan He
Tao Xu
Feng-min Yue
Liang-lu Wang
Hong-yu Zhang
Shi-tai Ye

Mots clés

Abstrait

OBJECTIVE

To evaluate the values of intradermal skin test (IDT) and serum specific IgE detection in diagnosing Humulus scandens sensitivity in Chinese patients with autumnal hay fever.

METHODS

1150 patients, 504 males and 646 females, aged 5 approximately 75, were evaluated as with autumnal rhinitis and asthma by experienced physicians. Then the patients underwent IDT by using 20 kinds of aeroallergen extracts, at the concentration of 1:1000 (w/v) for Artemisia spp. and ragweed or at the concentration of 1:100 (w/v) for Humulus scandens and others. The Humulus sIgE level was performed in all patients. A diagnosing criteria was established according to typical history, symptoms, and any one of the following findings: (1) wheal > or = 5 mm in diameter by IDT and sIgE to Humulus of the concentration > or = 0.35 kUa/L at same time; (2) wheal > or = 10 mm in diameter by IDT alone; and (3) sIgE to Humulus of the concentration > or = 0.70 kUa/L alone.

RESULTS

When using the above diagnosing criteria as the reference standard, IDT had better sensitivity (97.2%), positive predictive value (PV+) (77.9%), negative predictive value (PV-) (90.6%) and efficiency (80.4% than using sIgE > or = 0.35 kUa/L alone as the reference criteria of IDT, however, had a lower specificity (49.8%); and sIgE detection had better sensitivity (89.0%), specificity (97.5%), PV+ (98.8%), PV- (88.0%) and efficiency (92.0%) than using wheal > or = 5 mm in diameter alone as the reference criteria of sIgE detection. The false positive rate of IDT decreased from 59.9% to 17.4% when using wheal diameter > or = 10 mm as the positive criteria. In the 288 patients with a negative sIgE result and a positive IDT result 84 cases had stronger positive IDT result (with the wheal diameter > or = 10 mm).

CONCLUSIONS

IDT is correlated well with sIgE detection in diagnosing Humulus scandens pollinosis, but the false positive rate of IDT is higher than that of sIgE test. The false positive rate of IDT can be decreased by increasing the positive criteria to higher grading reaction. The immunotherapy according to the lower grading positive result of IDT alone or sIgE alone should be avoided.

Rejoignez notre
page facebook

La base de données d'herbes médicinales la plus complète soutenue par la science

  • Fonctionne en 55 langues
  • Cures à base de plantes soutenues par la science
  • Reconnaissance des herbes par image
  • Carte GPS interactive - étiquetez les herbes sur place (à venir)
  • Lisez les publications scientifiques liées à votre recherche
  • Rechercher les herbes médicinales par leurs effets
  • Organisez vos intérêts et restez à jour avec les nouvelles recherches, essais cliniques et brevets

Tapez un symptôme ou une maladie et lisez des informations sur les herbes qui pourraient aider, tapez une herbe et voyez les maladies et symptômes contre lesquels elle est utilisée.
* Toutes les informations sont basées sur des recherches scientifiques publiées

Google Play badgeApp Store badge