Français
Albanian
Arabic
Armenian
Azerbaijani
Belarusian
Bengali
Bosnian
Catalan
Czech
Danish
Deutsch
Dutch
English
Estonian
Finnish
Français
Greek
Haitian Creole
Hebrew
Hindi
Hungarian
Icelandic
Indonesian
Irish
Italian
Japanese
Korean
Latvian
Lithuanian
Macedonian
Mongolian
Norwegian
Persian
Polish
Portuguese
Romanian
Russian
Serbian
Slovak
Slovenian
Spanish
Swahili
Swedish
Turkish
Ukrainian
Vietnamese
Български
中文(简体)
中文(繁體)
Steroids 2020-Feb

Detection and quantitation of ecdysterone in human serum by liquid chromatography coupled to tandem mass spectrometry.

Seuls les utilisateurs enregistrés peuvent traduire des articles
Se connecter S'inscrire
Le lien est enregistré dans le presse-papiers
Gabriella Ambrosio
Jan Joseph
Bernhard Wuest
Monica Mazzarino
Xavier de la Torre
Patrick Diel
Francesco Botrè
Maria Parr

Mots clés

Abstrait

The polyhydroxylated phytosteroid ecdysterone is present in various plants (e.g. spinach). It is widely marketed as the active component of dietary supplements, due to its reported health and performance promoting effects. For evaluation of its actual bioavailability, a fast and sensitive method was developed, optimized and validated for human serum. Instrumental analysis was performed utilizing liquid chromatography-tandem mass spectrometry with positive electrospray ionization and acquisition in multiple reaction mode. Solid phase extraction and dilute-and-inject (following protein precipitation) were tested to isolate ecdysterone from human serum. Both methods were compared in the light of the preset analytical target profile. The limit of detection (LOD) and quantification (LOQ) for ecdysterone in human serum after SPE extraction corresponded to 0.06 ng/mL and 0.14 ng/mL, respectively, meeting the requested sensitivity of the method. The assay was linear over the range from 0.10 ng/mL to 20.83 ng/mL. As expected, the sensitivity of the SPE method was better than that of the dilute-and-inject procedure, which did not allow for quantification of all post administration serum samples. Accuracy (relative error; %) and precision (coefficient of variation; %), were both within acceptance criteria (<15%). The developed method was successfully applied to a ten week intervention study conducted in young men performing regular resistance training. Different doses of supplements containing ecdysterone from spinach extract have been administered during the study and the quantitation of ecdysterone in serum samples has been successfully conducted. Ecdysterone could be quantified in all post-administration samples using solid phase extraction (SPE) for sample pretreatment.

Rejoignez notre
page facebook

La base de données d'herbes médicinales la plus complète soutenue par la science

  • Fonctionne en 55 langues
  • Cures à base de plantes soutenues par la science
  • Reconnaissance des herbes par image
  • Carte GPS interactive - étiquetez les herbes sur place (à venir)
  • Lisez les publications scientifiques liées à votre recherche
  • Rechercher les herbes médicinales par leurs effets
  • Organisez vos intérêts et restez à jour avec les nouvelles recherches, essais cliniques et brevets

Tapez un symptôme ou une maladie et lisez des informations sur les herbes qui pourraient aider, tapez une herbe et voyez les maladies et symptômes contre lesquels elle est utilisée.
* Toutes les informations sont basées sur des recherches scientifiques publiées

Google Play badgeApp Store badge