Français
Albanian
Arabic
Armenian
Azerbaijani
Belarusian
Bengali
Bosnian
Catalan
Czech
Danish
Deutsch
Dutch
English
Estonian
Finnish
Français
Greek
Haitian Creole
Hebrew
Hindi
Hungarian
Icelandic
Indonesian
Irish
Italian
Japanese
Korean
Latvian
Lithuanian
Macedonian
Mongolian
Norwegian
Persian
Polish
Portuguese
Romanian
Russian
Serbian
Slovak
Slovenian
Spanish
Swahili
Swedish
Turkish
Ukrainian
Vietnamese
Български
中文(简体)
中文(繁體)
Environmental Science and Pollution Research 2020-May

Development of Low-Cost Paper-Based Biosensor of Polyphenol Oxidase for Detection of Phenolic Contaminants in Water and Clinical Samples

Seuls les utilisateurs enregistrés peuvent traduire des articles
Se connecter S'inscrire
Le lien est enregistré dans le presse-papiers
Rubia Noori
Mohammad Perwez
Jahirul Mazumder
Meryam Sardar

Mots clés

Abstrait

In the present work, polyphenol oxidase (PPO) enzyme was purified from potato peel using three-phase partitioning (TPP). In this method, ammonium sulfate and t-butanol were added to precipitate the protein/enzyme from the crude aqueous extract. The PPO enzyme precipitated as an interfacial layer between the upper organic solvent phase and lower aqueous phase. Different purification parameters such as crude extract to t-butanol ratio, ammonium sulfate concentration, temperature, and pH were optimized for TPP. About 69% PPO enzyme activity was recovered in a single step of TPP with 9.2-fold purification. The sodium dodecyl sulfate-polyacrylamide gel electrophoresis profile of partially purified PPO enzyme showed molecular weight in the range of about 30-40 kDa. The PPO enzyme was then investigated for the fabrication of a portable, cost-effective, and disposable colorimetric paper biosensor or colorimetric "test strips" for detection of phenolic contaminants. PPO and a chromophore reagent (3-methyl-2-benzothiazolinone hydrazine) generated a range of color in the presence of phenolic compounds (catechol, phenol, p-cresol, 4-methyl catechol) within 15 min, and limit of detection was found to be 0.5 μM. The biosensor worked in a broad range of pH from 3 to 11 and showed good storage stability at 25 °C and 4 °C for 30 days with no significant loss of activity. The biosensor was also applied on environmental water and urine sample to show reliability of biosensor.

Keywords: Biosensor; Catechol; Phenols; Pollutants; Polyphenol oxidase; Three-phase partitioning.

Rejoignez notre
page facebook

La base de données d'herbes médicinales la plus complète soutenue par la science

  • Fonctionne en 55 langues
  • Cures à base de plantes soutenues par la science
  • Reconnaissance des herbes par image
  • Carte GPS interactive - étiquetez les herbes sur place (à venir)
  • Lisez les publications scientifiques liées à votre recherche
  • Rechercher les herbes médicinales par leurs effets
  • Organisez vos intérêts et restez à jour avec les nouvelles recherches, essais cliniques et brevets

Tapez un symptôme ou une maladie et lisez des informations sur les herbes qui pourraient aider, tapez une herbe et voyez les maladies et symptômes contre lesquels elle est utilisée.
* Toutes les informations sont basées sur des recherches scientifiques publiées

Google Play badgeApp Store badge