Irish
Albanian
Arabic
Armenian
Azerbaijani
Belarusian
Bengali
Bosnian
Catalan
Czech
Danish
Deutsch
Dutch
English
Estonian
Finnish
Français
Greek
Haitian Creole
Hebrew
Hindi
Hungarian
Icelandic
Indonesian
Irish
Italian
Japanese
Korean
Latvian
Lithuanian
Macedonian
Mongolian
Norwegian
Persian
Polish
Portuguese
Romanian
Russian
Serbian
Slovak
Slovenian
Spanish
Swahili
Swedish
Turkish
Ukrainian
Vietnamese
Български
中文(简体)
中文(繁體)
Rapid Communications in Mass Spectrometry 2006

Identification and quantitation of phenolic compounds in faecal matrix by capillary gas chromatography and nano-electrospray mass spectrometry.

Ní féidir ach le húsáideoirí cláraithe ailt a aistriú
Logáil Isteach / Cláraigh
Sábháiltear an nasc chuig an gearrthaisce
Ulrike Knust
Gerhard Erben
Bertold Spiegelhalder
Helmut Bartsch
Robert Wyn Owen

Keywords

Coimriú

Very few relevant methods have been described for the detection and quantitation of phenolic compounds in faecal matrix. Extraction with conventional organic solvents such as chloroform/methanol (2:1, Folch reagent), methanol and ethanol (72%) showed high extraction efficiency for lipids and also gave good recovery of the major phenolic compounds present in the matrix. However, in comparison with a newly developed phosphate buffer method, the yield of minor phenolics was negligible when detected by these conventional methods. Conventional methods also lead to contamination of the ion source of the mass spectrometer and rapid deterioration of column performance mostly due to the high concentration of lipids. However, if the faecal matrix is initially extracted with phosphate buffer, and the extract acidified and re-extracted with diethyl ether, the range and yield of phenolic compounds are enhanced and the problem of lipid contamination is substantially alleviated. Following pilot studies and optimisation of the procedure, individual phenolic compounds (n = 29) were identified by nano-electrospray ionisation mass spectrometry (nano-ESI-MS), nano-ESI-tandem mass spectrometry (MS/MS) and gas chromatography/mass spectrometry (GC/EI-MS) and quantitated (n = 27) by GC/MS in subsets (n = 5) of faecal samples, collected during the European Agency for Cancer Prevention calcium/fibre intervention study from four European countries (Italy, Germany, Spain and Denmark). A range of phenolic compounds (mainly acids) was detected, dominated by phenylacetic, benzoic, phenylpropionic and m-hydroxyphenylpropionic acids, representing on average 9.91 (93%), 8.25 (92%), 9.45 (95%) and 11.05 (98%) mM in the Italian, German, Spanish and Danish samples, respectively. The new method should enable large epidemiologic, case-control and intervention studies on the relevance of phenolic antioxidants in the aetiology of colorectal cancer to be conducted in the future.

Bí ar ár
leathanach facebook

An bunachar luibheanna míochaine is iomláine le tacaíocht ón eolaíocht

  • Oibreacha i 55 teanga
  • Leigheasanna luibhe le tacaíocht ón eolaíocht
  • Aitheantas luibheanna de réir íomhá
  • Léarscáil GPS idirghníomhach - clibeáil luibheanna ar an láthair (ag teacht go luath)
  • Léigh foilseacháin eolaíochta a bhaineann le do chuardach
  • Cuardaigh luibheanna míochaine de réir a n-éifeachtaí
  • Eagraigh do chuid spéiseanna agus fanacht suas chun dáta leis an taighde nuachta, trialacha cliniciúla agus paitinní

Clóscríobh symptom nó galar agus léigh faoi luibheanna a d’fhéadfadh cabhrú, luibh a chlóscríobh agus galair agus comharthaí a úsáidtear ina choinne a fheiceáil.
* Tá an fhaisnéis uile bunaithe ar thaighde eolaíoch foilsithe

Google Play badgeApp Store badge