Irish
Albanian
Arabic
Armenian
Azerbaijani
Belarusian
Bengali
Bosnian
Catalan
Czech
Danish
Deutsch
Dutch
English
Estonian
Finnish
Français
Greek
Haitian Creole
Hebrew
Hindi
Hungarian
Icelandic
Indonesian
Irish
Italian
Japanese
Korean
Latvian
Lithuanian
Macedonian
Mongolian
Norwegian
Persian
Polish
Portuguese
Romanian
Russian
Serbian
Slovak
Slovenian
Spanish
Swahili
Swedish
Turkish
Ukrainian
Vietnamese
Български
中文(简体)
中文(繁體)
Journal of Electrocardiology 1984-Oct

Ventricular fibrillation: the importance of being coarse?

Ní féidir ach le húsáideoirí cláraithe ailt a aistriú
Logáil Isteach / Cláraigh
Sábháiltear an nasc chuig an gearrthaisce
D L Jones
G J Klein

Keywords

Coimriú

Ventricular fibrillation (VF) has been classified electrocardiographically as "fine amplitude" or "coarse amplitude" VF. It has been suggested that coarse VF represents increased "synchronization" of myocardial activation which could result in lower thresholds for defibrillation. To test the "synchronization" differences between coarse VF and fine VF, we induced VF in ten normal anaesthetized dogs. Standard limb lead and His bundle electrograms were recorded simultaneously with 12 bipolar epicardial electrograms (eight dogs) and six lead ECG (two dogs). Activation "synchronization" was assessed by calculating the standard deviations (SD) of electrogram activation times during one coarse VF and one fine VF cycle. Less synchronization during VF was indicated by a 50% larger SD (CVF: 29.3 +/- 1.1 msec, FVF: 32.6 +/- 1.6 msec) compared to ventricular pacing (21.2 +/- 1.6 msec) and 500% larger than sinus rhythm (6.5 +/- 0.5 msec). Coarse VF and fine VF did not differ. In addition, the 6-lead ECG recorded during early VF had episodes of coarse VF and fine VF occurring simultaneously. The amplitude of all electrograms diminished over 15 minutes until only fine VF could be recorded. We conclude that coarse VF does not reflect greater synchronization of activity than fine VF early in fibrillation (five minutes). Rather, differences are due to lead orientation. Later in the fibrillation bout, fine VF probably reflects metabolically induced degeneration of cellular excitability.

Bí ar ár
leathanach facebook

An bunachar luibheanna míochaine is iomláine le tacaíocht ón eolaíocht

  • Oibreacha i 55 teanga
  • Leigheasanna luibhe le tacaíocht ón eolaíocht
  • Aitheantas luibheanna de réir íomhá
  • Léarscáil GPS idirghníomhach - clibeáil luibheanna ar an láthair (ag teacht go luath)
  • Léigh foilseacháin eolaíochta a bhaineann le do chuardach
  • Cuardaigh luibheanna míochaine de réir a n-éifeachtaí
  • Eagraigh do chuid spéiseanna agus fanacht suas chun dáta leis an taighde nuachta, trialacha cliniciúla agus paitinní

Clóscríobh symptom nó galar agus léigh faoi luibheanna a d’fhéadfadh cabhrú, luibh a chlóscríobh agus galair agus comharthaí a úsáidtear ina choinne a fheiceáil.
* Tá an fhaisnéis uile bunaithe ar thaighde eolaíoch foilsithe

Google Play badgeApp Store badge