Hindi
Albanian
Arabic
Armenian
Azerbaijani
Belarusian
Bengali
Bosnian
Catalan
Czech
Danish
Deutsch
Dutch
English
Estonian
Finnish
Français
Greek
Haitian Creole
Hebrew
Hindi
Hungarian
Icelandic
Indonesian
Irish
Italian
Japanese
Korean
Latvian
Lithuanian
Macedonian
Mongolian
Norwegian
Persian
Polish
Portuguese
Romanian
Russian
Serbian
Slovak
Slovenian
Spanish
Swahili
Swedish
Turkish
Ukrainian
Vietnamese
Български
中文(简体)
中文(繁體)
Kaku igaku. The Japanese journal of nuclear medicine 1996-Mar

[A new method for measurement of both regional cerebral blood flow and distribution volume using N-isopropyl-p-[123I]iodoamphetamine (123I-IMP) and SPECT].

केवल पंजीकृत उपयोगकर्ता ही लेखों का अनुवाद कर सकते हैं
साइन अप करने के लिए लॉग इन करें
लिंक क्लिपबोर्ड पर सहेजा गया है
M Ohkubo
I Odano
M Takahashi
E Noguchi
H Ohtaki
T Kasahara
M Hatano

कीवर्ड

सार

We developed a new method (functional IMP SPECT) to quantitate both regional cerebral blood flow (rCBF) and distribution volume (Vd) using 123I-IMP and SPECT based on a 2- compartment model (influx; K1 =rCBF and outflux; k2). This method requires one arterial blood sampling at 5 min after injection of the tracer and two SPECT scans at 30 min and 60 min. It takes approximately 60 min for total measurements. The integration of arterial input function is estimated by one blood sample taken at 5 min after injection of the tracer without octanol treatment, by using the correlation between one blood sample and the integration, which was obtained from studies on 25 subjects. With the value of integration, K1 and Vd are calculated from the data of two SPECT scans by using the mathematical functions based on the 2-compartment model, which were obtained from studies on 12 subjects. In the practical range of K1 (0.3-0.7 ml/g/min) and Vd (15-35 ml/g) given in the 2-compartment model, statistical errors of K1 and Vd obtained by the functional IMP SPECT were evaluated at approximately 14.0% and 17.2%, respectively. In clinical studies for eight subjects including two healthy volunteers, three patients with cerebral infarction and three patients with degenerative disease, K1 and Vd values estimated by the functional IMP SPECT were significantly correlated with those estimated by non-linear least squares fitting analysis based on the 2-compartment model, and the mean errors of K1 and Vd estimated by the functional IMP SPECT were approximately 8.0% and 11.2% respectively, suggesting the validity of the new method. We conclude that the functional IMP SPECT is clinically useful because of the accuracy, less-invasiveness and convenience.

हमारे फेसबुक पेज से जुड़ें

विज्ञान द्वारा समर्थित सबसे पूर्ण औषधीय जड़ी बूटी डेटाबेस

  • 55 भाषाओं में काम करता है
  • विज्ञान द्वारा समर्थित हर्बल इलाज
  • छवि द्वारा जड़ी बूटी की मान्यता
  • इंटरएक्टिव जीपीएस नक्शा - स्थान पर टैग जड़ी बूटियों (जल्द ही आ रहा है)
  • अपनी खोज से संबंधित वैज्ञानिक प्रकाशन पढ़ें
  • उनके प्रभाव से औषधीय जड़ी बूटियों की खोज करें
  • अपने हितों को व्यवस्थित करें और समाचार अनुसंधान, नैदानिक परीक्षणों और पेटेंट के साथ अद्यतित रहें

एक लक्षण या बीमारी टाइप करें और जड़ी-बूटियों के बारे में पढ़ें जो मदद कर सकती हैं, एक जड़ी बूटी टाइप करें और बीमारियों और लक्षणों को देखें जिनके खिलाफ इसका उपयोग किया जाता है।
* सभी जानकारी प्रकाशित वैज्ञानिक शोध पर आधारित है

Google Play badgeApp Store badge