Journal of Chromatography A 2003-Nov

Evaluation of modulators and electron-capture detectors for comprehensive two-dimensional GC of halogenated organic compounds.

केवल पंजीकृत उपयोगकर्ता ही लेखों का अनुवाद कर सकते हैं
साइन अप करने के लिए लॉग इन करें
लिंक क्लिपबोर्ड पर सहेजा गया है
E Maria Kristenson
Peter Korytár
Conny Danielsson
Minna Kallio
Menno Brandt
Jani Mäkelä
René J J Vreuls
Jan Beens
Udo A Th Brinkman

कीवर्ड

सार

Different cryogenic and a heated GC x GC modulator(s) were evaluated and compared for the analysis of high-boiling halogenated compounds. The cryogenic modulators investigated were: (i) the longitudinally modulated cryogenic system; (ii) the liquid-nitrogen-cooled jet modulator (KT2001); (iii) a dual-jet CO2 modulator (made in-house); (iv) a semi-rotating cryogenic modulator (made in-house) and (v) a CO2 loop modulator (KT2003); the heated modulator was the slotted heater system (sweeper). Each modulator was optimised with respect to analyte peak widths at half height in the second-dimension. n-Alkanes, chlorinated alkanes, polychlorinated biphenyls (PCBs) and fluorinated polycyclic aromatic hydrocarbons (F-PAHs) were used as test analytes. The flow rate of the coolant was found to be an important parameter, i.e. the flow rate of the gaseous nitrogen in the KT2001, and of the liquid CO2 in the other cryogenic modulators. For the slotted heater the stroke velocity and pause time were important parameters. This modulator had a limited application range in terms of temperature due to a necessary 100 degrees C difference between sweeper and oven temperature. All cryogenic modulators were found to be suitable for the GC x GC analysis of high-boiling compounds, but the CO2 modulators are to be preferred to the KT2001 due to a wider application range and slightly narrower peaks. As regards the performance of three commercially available electron-capture detectors (ECDs), the aim was to obtain narrow peak widths in GC x GC, i.e. to avoid band broadening caused by the cell volume. The most important parameters were the flow rate of the make-up gas and the detector temperature which both should be as high as possible. Comparison of analyte peak widths obtained with ECD mode and flame ionisation detection (FID) showed that all ECDs exhibited band broadening compared to the FID. The narrowest peaks were obtained with the Agilent micro-ECD, which has a cell volume of only 150 microl.

हमारे फेसबुक पेज से जुड़ें

विज्ञान द्वारा समर्थित सबसे पूर्ण औषधीय जड़ी बूटी डेटाबेस

  • 55 भाषाओं में काम करता है
  • विज्ञान द्वारा समर्थित हर्बल इलाज
  • छवि द्वारा जड़ी बूटी की मान्यता
  • इंटरएक्टिव जीपीएस नक्शा - स्थान पर टैग जड़ी बूटियों (जल्द ही आ रहा है)
  • अपनी खोज से संबंधित वैज्ञानिक प्रकाशन पढ़ें
  • उनके प्रभाव से औषधीय जड़ी बूटियों की खोज करें
  • अपने हितों को व्यवस्थित करें और समाचार अनुसंधान, नैदानिक परीक्षणों और पेटेंट के साथ अद्यतित रहें

एक लक्षण या बीमारी टाइप करें और जड़ी-बूटियों के बारे में पढ़ें जो मदद कर सकती हैं, एक जड़ी बूटी टाइप करें और बीमारियों और लक्षणों को देखें जिनके खिलाफ इसका उपयोग किया जाता है।
* सभी जानकारी प्रकाशित वैज्ञानिक शोध पर आधारित है

Google Play badgeApp Store badge